HP XP P9000 Continuous Access Journal for Mainframe Systems User Guide
Figure 19 Typical SIM with reference code and SIM type
The following table shows SIM reference codes, and provides useful information for identifying
issues and determining the system experiencing the problem. All SIMs are reported to the host,
except 21 80, 21 81, and possibly DC EX—depending on the value set for system option mode
598. For more information, see “System option modes ” (page 38).
SVP log fileSystem generating the
SIM
DescriptionSeverityReference code
Byte 23Byte 22
SIM LogPrimary/SecondaryA logical path is blocked due to failure.Moderate8021
SSB LogPrimary/SecondaryThe logical path is restored.Service8121
SIM LogPrimary/SecondaryA line failure is reported by the extender.Moderate8221
SIM LogPrimaryThe P-VOL has been suspended.Serious0XDC
Path recovery is impossible.
SIM LogPrimaryThe P-VOL has been suspended.Serious1XDC
A failure has been detected in the primary
system.
SIM LogPrimaryThe P-VOL has been suspended.Serious2XDC
A failure has been detected in the
secondary system.
SIM LogPrimaryThe P-VOL has been suspended.Serious4XDC
The pair has been suspended at the
secondary system.
SIM LogPrimaryThe P-VOL has been suspended.Serious5XDC
A pair has been released at the
secondary system.
SIM LogPrimaryThe S-VOL has been suspended.Serious6XDC
Path recovery is impossible.
SIM LogSecondaryThe S-VOL has been suspended.Serious7XDC
A failure has been detected in the
secondary system.
PrimaryYes, repeatedly.A delta resync P-VOL has been
suspended.
Serious9XDC
A failure has been detected in the primary
system.
Service information messages (SIMs) 129