HP XP P9000 Continuous Access Journal for Mainframe Systems User Guide
Corrective actionDescriptionPath status
Restore the path
*
.This path was not established.<blank>
* To restore a path, delete and then add the path again. It may be necessary to delete and then add the RCU again.
To delete the RCU or path, see (page 101) or (page 100). To re-register, see (page 60). If you cannot restore the path after performing
these operations, contact HP for assistance.
Troubleshooting by suspension type
Troubleshooting information for suspended pairs by suspension type is provided in the following
table.
Corrective ActionDescriptionApplies toSuspend Type
Restore the pair from the primary system.The user suspended the pair from the
primary or the secondary system by using
the S-VOL option.
P-VOL, S-VOLSecondary Data
Volume by
Operator
Clear the error condition at the secondary
system or S-VOL. If you need to access the
The primary system suspended a pair
because the system detected an error
condition at the secondary system.
P-VOLby RCU
S-VOL, release the pair from the secondary
system. If any data on the S-VOL has
changed, release the pair from the primary
system and then re create the pair (Add Pair).
If data on the S-VOL has not changed, restore
the pair from the primary system.
Release the pair from the primary system, and
then restore the pair. You should use the Entire
The primary system detected that the
S-VOL status changed to Simplex because
P-VOLDelete Pair to RCU
initial copy option to resynchronize the pair.the user released the pair from the
secondary system. You can use the None initial copy option only
if no data on the P-VOL or S-VOL changed.
Check the path status (see “Troubleshooting
logical paths ” (page 114)).
The primary system detected an error
during communication with the secondary
P-VOLSecondary Data
Volume Failure
Clear any error conditions at the secondary
system and the S-VOL. If you need to access
system or detected an I/O error during
update copy. In this case, the suspend
type for the S-VOL is usually by MCU.
the S-VOL, release the pair from the secondary
system. If data in the S-VOL has been
changed, release the pair from the primary
system and then re-create the pair. If data in
the S-VOL has not been changed, restore the
pair from the primary system.
Restore the pair (pairresync) from the primary
system. The primary system performs an initial
The primary system could not find valid
control information in its nonvolatile
P-VOL, S-VOLMCU IMPL
copy operation in response to the pairresyncmemory during the IMPL procedure. This
request; the entire P-VOL is copied to the
S-VOL.
error occurs only if the primary system is
without power for more than 48 hours
(power failure and fully discharged
batteries).
Release the pair from the primary system.
Clear all error conditions at the primary
The primary system suspended this pair
during the initial copy operation. The data
P-VOL, S-VOLInitial Copy Failed
system, the P-VOL, the secondary system, andon the S-VOL is not identical to the data
the S-VOL. Reformat failed track by usingon the P-VOL. Invalid track format can
cause this suspension. ICKDSF. Restart the initial copy operation by
using the Add Pair dialog box.
None. The primary system automatically
restores these Cnt Ac-J Z pairs when it is
powered on.
The primary system suspended all Cnt Ac-J
Z pairs because it was powered off.
S-VOLMCU P/S-OFF
116 Troubleshooting