HP XP P9000 Business Continuity Manager User Guide (T5253-96086, November 2013)
Table 20 Copy pair statuses of volumes obtained by the YKQRYDEV command (Cnt Ac-J Z)
DescriptionStatus of the copy pair in the
storage system
Copy pair status acquired by
YKQRYDEV
SIMPLEX status.SimplexSIMPLEX
The copy pair is changing to the DUPLEX status (during
an initial copy or resynchronization).
Duplex PendingPENDING (01)
DUPLEX status.DuplexDUPLEX (02)
The user has suspended the copy pair from the P-VOL.SuspendedSUSPOP (03)
The user has suspended the S-VOL. (The P-VOL has been
updated and the differential data between the P-VOL and
S-VOL is being recorded.)
SuspendedSUSPOP (04)
The user has suspended a copy pair for which REVERSE
is specified.
SuspendedSWAPPING (04)
The copy pair has been suspended because the secondary
storage system has received a suspend request from the
primary storage system.
SuspendedSUSPOP (05)
The copy pair has been suspended because the primary
storage system has detected an error status on the
secondary storage system.
SuspendedSUSPCU (06)
The P-VOL has been suspended because the user dissolved
the copy pair from the S-VOL (changed to the SIMPLEX
status).
SuspendedSUSPER (07)
The copy pair has been suspended because the primary
storage system detected either an error during migration
SuspendedSUSPCU (08)
with the secondary storage system or an I/O error during
update copying.
The copy pair has been suspended because, when the
power was turned on (IMPL), the primary storage system
SuspendedSUSPER (09)
detected that the pair control information that had been in
memory was no longer available (that is, the information
had been lost). This error occurs when the primary storage
system was turned off for a period that exceeded the
backup period for non-volatile memory.
The copy pair has been suspended because the data
between the P-VOL data and the S-VOL data did not match
SuspendedSUSPER (50)
during the initial copying phase. Invalid track formatting
causes this error.
The copy pair is changing to the suspend status.SuspendingTRANS (60)
The copy pair is changing to the Simplex status.DeletingTRANS (61)
The primary storage system has suspended all the copy
pairs due to a planned outage (turned off).
SuspendedSUSPER (62)
Copy pairs are ready to perform a Delta Resync, and a
Delta Resync can be performed.
HOLDHOLD (70)
A transition to HOLDER status indicates that the differential
data cannot be kept in a journal due to a hardware failure
HOLDERHOLDER (71)
such as a cache memory, shared memory, or journal
volume failure.
The status of a Delta Resync pair is being changed to the
HOLD status.
HOLDTRNSHOLDTRNS (72)
The user tried to perform a Delta Resync, but the copy pair
changed to the HOLDER status because the copy pair is
HOLDERHOLDER (73)
82 Business Continuity Manager with replication products