HP XP P9000 Business Continuity Manager User Guide (T5253-96086, November 2013)
Operating procedure during a storage system failure (with information lost from
memory) at remote site 1 or 2
The following are the procedures that must be performed when a storage system failure, with
information lost from memory, occurs at remote site 1 or 2.
The procedure below applies when a storage system failure occurs at remote site 1. If a storage
system failure occurs at remote site 2, replace remote site 1 with remote site 2 in the procedure.
Preparing
No action is required.
Recovering
1. Recover the storage system at remote site 1 from the failure.
2. From the primary site, execute the YKDELETE command for the Continuous Access Journal Z
copy pair between the primary site and remote site 1.
• YKQUERY
• YKDELETE
• YKEWAIT GOTO(SIMPLEX) NOINVALIDCHECK
Using a 3DC Multi-Target (Cnt Ac-J Z x Cnt Ac-J Z) configuration 397