HP XP P9000 Business Continuity Manager User Guide (T5253-96086, November 2013)
Steps on the secondary host (3DC Cascade configuration)
1. Scan the storage system at the remote site:
• Perform a scan over a range that contains volumes to be defined in the copy group and
a command device (for the reverse direction) to be registered in the storage system of
the remote site.
• A DAD ID assigned by a scan (Local Device Address Domain ID in the Set Defaults panel)
must be the same DAD ID assigned by performing a remote scan at the remote site from
the primary host.
For details on how to perform a scan to acquire storage system information, see “Acquiring
volume information” (page 588).
2. Define a path set consisting of inter-CU logical paths (Intermediate → Primary) and inter-DKC
logical paths (Remote → Intermediate) that are in the reverse direction (or specify a path using
Remote Web Console).
A CU to be specified for a path set must include a volume to be defined in a Cnt Ac-S copy
group and a command device for the reverse direction.
3. Create a route list for the reverse direction (Remote → Intermediate → Primary route).
Defining a 3DC Cascade (Cnt Ac-S Z x Cnt Ac-J Z) configuration 159