HP StorageWorks P9000 Virtualization Adapter Administrator Guide (5697-0680, October 2010)

%HORCMROOT%\HORCM\etc\raidscan −IH −p port(i.e. cl1-a-0) −CLI (port
where connecting to ESX server)
If Business Copy is installed:
%HORCMROOT%\HORCM\etc\pairdisplay −g ??? −CLI −l −few −m cas (where
??? is a group name shown by “raidqry −g”)
For SRM and the P9000 Virtualization Adapter remote configuration:
On Windows where SRM is performing and on UNIX where RAID Manager is performing:
1. Collect the SRM log file on Windows on both the protection and recovery sites.
Collect the following SRM log file, including the error messages of the P9000 Virtualization
Adapter, SRM ERROR messages, and RAID Manager command error log:
%ALLUSERSPROFILE%\ Application Data\VMware\VMware Site Recovery
Manager\Logs\vmware*.log
2. Collect the Outputs of the following command on HORCMINST=XX (instance# for the P9000
Virtualization Adapter) on remote UNIX.
env
raidqry -l
raidqry -g
pairdisplay −IH −g ??? −CLI −l −fwe (where ??? is a group name shown
by “raidqry −g”)
raidscan −IH −p port(i.e. cl1-a-0) −CLI (port where connecting to
ESX server)
If Business Copy is installed:
pairdisplay −g ??? −CLI −l −few −m cas (where ??? is a group name
shown by “raidqry −g”)
Error code for multiple errors
The P9000 Virtualization Adapter defines an error code using a 32-bit OR flag, so multiple errors
can be identified. Errors are described in following table.
For example:
[RMSRA][Sun Aug 3 16:25:56 2008]: [command_main] : 'testFailover_start' failed with
error(0x00002000) on arrayId(64015).
ReasonError Code
XX : exit code returned from RAID Manager command.
See the RAID Manager command error code.
0x000000XX
The volume is inappropriate property as SMPL.0x00000100
The volume is inappropriate property as P-VOL.0x00000200
The volume is inappropriate property as S-VOL.0x00000400
Undefined.0x00000800
The volume is inappropriate status as COPY , etc0x00001000
P9000 Virtualization Adapter Administrator Guide 47