HP StorageWorks P9000 Virtualization Adapter Administrator Guide (5697-0680, October 2010)

CauseA parameter in XML was entered from SRM to the P9000 Virtualization Adapter, but it
could not be found in any parameters.
Action to be takenConfirm that SRM has passed appropriate parameters in XML from its own
SRM log message.
[P9000 Virtualization Adapter] [Time]: [command_discoverLuns] : NO arrayId in XML.
CauseA parameter in XML (discoverLuns) was entered from SRM to the P9000 Virtualization
Adapter, but it could not find the Array ID.
Action to be takenConfirm that SRM has passed Array ID parameter in XML (discoverLuns) from
own SRM log message.
[P9000 Virtualization Adapter] [Time]: [command_failover] : NO ReplicaLunKey in XML.
CauseA parameter in XML (failover) was entered from SRM to the P9000 Virtualization Adapter,
but it could not be found ReplicaLunKey (LDEV number of Continuous Access_S-VOL).
Action to be takenConfirm that SRM has passed ReplicaLunKey parameter in XML (failover) from
own SRM log message.
[P9000 Virtualization Adapter] [Time]: [command_testFailover] : Action in XML was NOT start/stop.
CauseA parameter in XML failover test was entered from SRM to the P9000 Virtualization Adapter,
but it could not be found start/stop as Action.
Action to be takenConfirm that SRM has passed start/stop parameter in XML failover test from
own SRM log message.
[P9000 Virtualization Adapter] [Time]: [command_testFailover] : NO ReplicaLunKey in XML.
CauseA parameter in XML failover test was entered from SRM to the P9000 Virtualization Adapter,
but it could not be found ReplicaLunKey (LDEV number of Continuous Access_S-VOL).
Action to be takenConfirm that SRM has passed ReplicaLunKey parameter in XML failover test
from own SRM log message.
[P9000 Virtualization Adapter] [Time]: [command_main] : Can't be connected to HORCMINST=X@
with error(0x000000fc).
CauseA connection address in XML was entered from SRM to the P9000 Virtualization Adapter,
but it could not be found HORCM instance number X.
Action to be takenCheck that HORCM instance number is running, or a connection address
(Alias) specified in configuration of Array Manager is appropriate.
RAID Manager command errors in rmsra.exe
[P9000 Virtualization Adapter] [Time]: [ XML OUTPUT file name] : fopen : system error message
CauseA parameter in XML was entered from SRM to the P9000 Virtualization Adapter, but it
could not be created XML OUTPUT file name.
Action to be takenConfirm that SRM has passed appropriate output file in XML from own SRM
log message, or take action by referring to system error message.
[P9000 Virtualization Adapter] [Time]: [system()] : Command line : system error message
CauseAn execution of Command line has failed via system() call.
Action to be takenConfirm that RAID Manager is installed, or the path of Command line is correct,
or %HORCMROOT% ENV has been set, or make action by referring to system error message.
[P9000 Virtualization Adapter] [Time]: [Command line] : popen : system error message
CauseAn execution of Command line has failed via popen() call.
Action to be takenConfirm that RAID Manager is installed, or the path of Command line is correct,
or %HORCMROOT% ENV has been set, or make action by referring to system error message.
Troubleshooting44