2 Code Converter Functions
This chapter describes Code Converter's available functions, their concept of operations, and when
they are used by an operator.
Alphanumeric Character Conversion Function, page 20
Double-byte Character Conversion Function, page 21
Non-conversion Function (Simple Transmission), page 22
Output Suppression Function, page 22
Numeric Conversion Function, page 23
Code Conversion Functions, page 24
The following table shows the Code Converter function specifications.
Table 1 Code Converter Functions
RemarksSpecificationFunction
None
Code conversion is performed only
on single-byte field data characters.
Mainframe > EBCDIC
Open system > ASCII
NOTE:
Single-byte character codes are
changed.
Alphanumeric character conversion
function
None
Code conversion is performed on
field data characters that are only
double-byte characters, or that are
double-byte characters and
single-byte characters, intermingled.
Mainframe > IBM Traditional
Chinese
Open system > Big5
NOTE:
Double-byte character codes are
changed.
Double-byte character conversion
function
Input data is not limited to
characters.
The data in the input field is not
changed and is output.
Non-conversion function (= simple
transmission)
The output field is shortened by
the length of the non-conversion
field that is not output.
The data in the input field is not
output.
Output suppression function
P9000 Data Exchange Code Converter User Guide 19