HP P9000 Provisioning for Open Systems User Guide (AV400-96396, October 2011)
RAID
Manager
RWCParameter settingsTaskElement
NoYesMonitoring mode
YesYesAdd pool-VOLs
NoYesDelete pool-VOLs
YesYesRestore pools
YesNoMonitoring start/end
YesNoTier relocation start/stop
YesYesCreateCreateTHP V-VOL
YesYesTHP V-VOL name
NoNoSmart Pool relocation: Disable
NoYesTiering policy
YesYesExpand
YesYesDiscard zero data
YesYesDelete
YesYesChange settingsChange settings
YesYesTiering policy
YesYesTiering policy
NoYesDownload tier relocation logRelocation
log
Notes:
1. Set to Disable if the pool is created by RAID Manager.
2. You can rename a pool when adding pool-VOLs to it.
3. Recommended setting is 0% for SSD and 8% for non-SSD drives.
Display items and parameters settings
RAID
Manager
RWCOutput informationCategory
YesYesSmart Pool: DisableTHP pool
YesYesTier Management mode: Auto/Manual
YesYesBuffer space for New page assignment (per tier)
NoYes*Cycle Time
NoYes*Monitoring Period
NoYesMonitoring mode
YesYesTier relocation: Enable/DisableTHP V-VOL
YesYesTiering policy
*You can view this item only in Auto mode.
Smart Tiers 93