HP P9000 Provisioning for Open Systems User Guide (AV400-96396, October 2011)
where
• the value enclosed in ceil( ) must be rounded up to the nearest whole number.
• calculated-management-area-capacity depends on volume emulation types and
RAID levels (see “Management area capacity of an open-systems volume” (page 49)).
To calculate the entire capacity of a CV if the data protection level is set to the Enhanced mode
on the SATA drive:
ceil(entire-capacity-of-a-CV(slots) +
calculated-management-area-capacity)
To convert the resulting entire capacity into blocks:
calculated-entire-capacity-of-a-CV(slots) *
capacity-of-a-slot * 2
where
• calculated-entire-capacity-of-a-CV(slots) means the entire capacity of a CV
if the data protection level is set to the Enhanced mode on the SATA drive.
Management area capacity of an open-systems volume
Management area capacity (KB)Emulation type
NoneOPEN-V
5,760OPEN-3
19,440OPEN-8
19,440OPEN-9
13,680OPEN-E
Boundary values for RAID levels other than Enhanced mode on SATA drives
Boundary values of external volumes are always one kilobyte, regardless of RAID levels.
Boundary value (KB)Emulation type
RAID 6 (6D+2P)RAID 5 (7D+1P)RAID 5 (3D+1P)RAID 1 (2D+2D)
2,3042,6881,152768Other than OPEN-V
3,0723,5841,5361,024OPEN-V
Boundary values for RAID levels (enhanced data protection level on SATA drives)
A SATA drive supports the OPEN-V emulation type for an open system.
Boundary value (KB)Emulation type
RAID 6 (6D+2P)RAID 5 (7D+1P)RAID 5 (3D+1P)RAID 1 (2D+2D)
24,57628,6726,1442,048OPEN-V
Capacity of a slot
Capacity (KB) of a slotEmulation type
48Other than OPEN-V
256OPEN-V
VLL size calculations 49