Table 62 Details of Error Codes C3xx (continued)
Type of ErrorError DetailsError
Code
OthersPATHCMDCnt Ac-J ZTCACnt Ac-S ZBC Z
Not outputOutputNot
output
The subsystem level cache of the
RCU is not valid.
C37C
Not outputOutputNot
output
The RCU is not NVS ON.C37D
Not outputOutputNot
output
The device level cache of the S-VOL
is not valid.
C37E
Not outputOutputNot
output
The S-VOL is not DFW ON.C37F
Not outputOutputNot
output
The cache for the MCU is blocked
on one side (in transition).
C380
Not outputOutputNot
output
The cache for the MCU is being
recovered.
C381
Not outputOutputNot
output
The cache for the MCU is being
blocked on one side (in transition)
C382
or it is being recovered on one
side.
Not outputOutputNot
output
RCU is already in use by Cnt Ac-S
Z or TCA.
C38B
Not outputOutputNot
output
The S-VOL device is not supported
by Cnt Ac-S Z or TCA.
C38E
Not outputOutputNot
output
The S-VOL is not in the suspend
status.
C390
Not outputOutputNot
output
The S-VOL is in a copy pair status
that does not permit copying.
C391
Not outputOutputNot
output
The S-VOL is online. Alternatively,
a copy pair was already made for
C392
a copy type other than Cnt Ac-S Z
or TCA.
Not outputOutputNot
output
The S-VOL has PIN data.C393
Not outputOutputNot
output
The S-VOL is online.C394
Not outputOutputNot
output
The S-VOL cannot be used
(because of a logical volume being
C395
blocked, collection access, and so
on).
Not outputOutputNot
output
The P-VOL capacity exceeds the
volume capacity within which a
copy pair can be made.
C39E
Not outputOutputNot
output
The P-VOL or S-VOL capacity
exceeds the volume capacity within
which a copy pair can be made.
C39F
Not outputOutputNot
output
The P-VOL device is not supported
by Cnt Ac-S Z or TCA.
C3A0
Not outputOutputNot
output
RCU does not support the S-VOL
host online check indication
function.
C3A4
Details of Error Codes 213