Table 44 Business Continuity Manager Error Messages and Corresponding Troubleshooting Actions
(Message ID YKZ40x) (continued)
Explanation and Recommended ActionsMessage TextMessage ID
4: Suspension was performed because the system
detected a no-update journal.
ss (decimal number)
Status of BC Z (0-3)
0: The suspend processing has not started.
1: The suspend processing is in progress.
2: The suspend processing ended successfully.
3: The suspend processing ended abnormally.
uu (decimal number)
Status of Cnt Ac-J Z (0 or 1)
0: All Cnt Ac-J Z copy pairs were in the DUPLEX
status during the suspension.
1: During the suspension, there was a Cnt Ac-J Z
copy pair whose status was not DUPLEX.
eeee (hexadecimal number)
Error information on suspend processing
0001: Suspension is not possible because the BC Z
copy pair status is invalid.
0002: Suspension is not possible because an error
occurred due to a problem in storage system.
ATTIME-suspend-time (GMT)
ATTIME suspend time:
YYYYMMDD-HH:MM:SS.NNNNNN
YYYY: Year
MM: Month
DD: Day
HH: Hour
MM: Minute
SS.NNNNNN: Second
The suspend processing started when the timeout
period elapsed because this period elapsed before
The timeout limit expired during the
wait for the reservation time of the
YKZ409E MSG SC=24
RC=24
the journal of the ATTIME suspend times for theCAJ ATTIME suspension. (CT ID=ii,
ATTIME suspend function was acquired, or theR-JNL=jj, GENID=gg,
TIME=ATTIME-suspend-time) suspend processing started at the ATTIME suspend
time because the Cnt Ac-J Z copy pair was in the
suspend status at the ATTIME suspend time.
Check the following because the backup for the
specified time might not have been acquired:
• Status of the Cnt Ac-J Z copy pair path
• Value specified for the TIMEOUT parameter of
the YKSUSPND command
• Status of the BC Z copy pair volumes (the Cnt Ac-J
Z consistency time and status during the
suspension)
• Status of the Cnt Ac-J Z copy pair volumes
After checking the results, if necessary, use the
YKSUSPND command to cancel the ATTIME suspend
information, and then re-acquire the backup.
ii (hexadecimal number)
List of Messages 153