HP P9000 External Storage for Open and Mainframe Systems User Guide (AV400-96392, October 2011)

If the status of the external volume changes to Blockade, the external volume will be automatically
restored in several hours. You can also manually restore the external volumes by using the Reconnect
External Volumes command.
Thunder 9500V storage system
System parameters
The following table explains whether to specify system parameters when making settings on ports
on the Thunder 9500V storage system.
Table 13 System parameters (9500V)
Parameter settingsParametersWindow names
Start AttributeSystem Startup Settings
Specify this parameter when Thunder 9500V storage
system is in the one controller configuration.
Single Mode
Specify this parameter when Thunder 9500V storage
system is in the two controller configuration.
Dual Active Mode
Be sure to specify that Data Share Mode will be used.
Do not specify this parameter.Hot Stand-By Mode
This parameter is optional.Delay Planned ShutdownCommon 1
This parameter is optional.SCSI Fibre Channel Common OptionsOPTION 1
This parameter is optional.SCSI Fibre Channel Common OptionsOPTION 2
Specify this parameter to Reset if it occurred.Operation if the processor failure
occurs
Data Striping
Specify this parameter ON.Command Queuing ModeInquiry Setting
Keep this parameter as Hitachi (default).Vendor ID
Keep this parameter as DF600F (default).Product ID
This parameter is optional.ROM Microprogram Version
This parameter is optional.RAM Microprogram Version
This parameter is optional.WEB Title
Reset/LIP ModePort Type
This parameter is optional.Reset/LIP Mode (Signal)
This parameter is optional.Reset/LIP Mode (Process)
This parameter is optional.LIP Reset Mode
This parameter is optional.RS232C Error Information Outflow
Mode
Controller Option
Set this parameter to ON.Write and verify mode
Set this parameter to Standard Mode.Host Connection Mode 1Host Connection Mode
Specify HISUP Mode.Host Connection Mode 2
Do not specify any other parameters.
72 Connecting external storage systems