Table 18 Status, availability of DRU operation (continued)
Referencing access attributeChanging access attributePair statusContinuous
Access
Synchronous
volume
YesYesPSUS
YesYesPSUE
YesYesSMPLS-VOL
YesNoCOPY
YesNoPAIR
YesNo*PSUS
YesNoPSUE
* If the S-VOL Write option is enabled, the access attribute can be changed.
The following table indicates whether a DRU volume with the specified access attribute can be
used as a Continuous Access Synchronous P-VOL or S-VOL.
Table 19 DRU access attribute with Continuous Access Synchronous P-VOL/S-VOL
Availability for Continuous Access Synchronous P-VOL or S-VOLDRU access attribute
S-VOLP-VOLRead/Write
YesYes
YesYesRead Only
YesYesProtect
NoYesS-VOL Disable
NoYesRead Only and S-VOL Disable
NoYesProtect and S-VOL Disable
Thin Provisioning Z
The virtual volume of Thin Provisioning Z (V-VOL) can be assigned as a part of Cnt Ac-S Z pair. A
Cnt Ac-S Z pair creation with a V-VOL and a not-V-VOL is also available. See the following table
for the details.
Table 20 Cnt Ac-S Z pair availability with V-VOL and not-V-VOL
S-VOLP-VOL
( Device emulation type )( Device emulation type )
not-V-VOL ( 3390-X
*1
)not-V-VOL ( 3390-A )V-VOL ( 3390-A )
Not availableAvailableAvailableV-VOL ( 3390-A )
Not availableAvailableAvailablenot-V-VOL ( 3390-A )
AvailableAvailableAvailablenot-V-VOL ( 3390-X
*1
)
*1
The 3390-X above represents the device emulation types of 3390 series except 3390-A. (see
Table 6 (page 16) for the 3390 device emulation types supported by Cnt Ac-S Z.) The V-VOL
combined with the device types other than 3390 is not available.
To enable the data migration from existing storage to the V-VOL (3390-A) or not-V-VOL (3390-A),
a combination of the not-V-VOL (3390-X) as the P-VOL and the V-VOL (3390-A) or not-V-VOL
38 Sharing Continuous Access Synchronous volumes