HP P9000 Continuous Access Synchronous for Mainframe Systems User Guide (AV400-96398, October 2011)

Table 25 Sample settings
Round Trip
Time
Specified[ms]
Number of Maximum
Initial Copy VOLs
Initial Copy PaceNumber of Lines
b/w MCU/RCU
Line Speed b/w
MCU/RCU
[MB/ms]
Round Trip Time
between MCU
RCU[ms]
160641540.10
220641540.130
360641540.1100
If using XP12000 Disk Array/XP10000 Disk Array: Set the following parameters using use
the System Option window.
Maximum Initial Copy Activity
Path Blockade Watch
16. Click Set.
17. Review the Preview list. To change a path, right-click it in the Preview list and select Modify.
Make any changes in the Add Path dialog box then click Set. To delete the added logical
path(s), right-click it in the Preview list and select Delete.
18. When satisfied, click Apply. This saves the configuration.
Configure additional logical paths
You can configure additional logical paths as needed. A maximum of eight logical paths are
supported.
Prerequisite information
Logical paths can be added from the main or remote system.
Please review the path-related prerequisites in “Configure disk arrays and define logical paths
(page 46).
Procedure 2 To configure additional logical paths
1. On the menu bar, click Actions > Remote Copy > Continuous Access Synchronous for Mainframe
> RCU Operation. The RCU Operation window opens.
2. Change to Modify mode by clicking the icon.
3. In the Display box, select MCU&RCU.
4. In the tree, open the main system CU grouping and CU, then select the desired RCU.
5. In the list area, right-click, then select Add Path from the menu. The Add Path dialog box
displays.
Configure additional logical paths 51