HP P9000 Continuous Access Synchronous for Mainframe Systems User Guide (AV400-96398, October 2011)

C Continuous Access Synchronous Z GUI reference
This appendix describes the Continuous Access Synchronous Z windows, dialog boxes, fields, and
behaviors in Remote Web Console.
Continuous Access Synchronous Z windows
Continuous Access Synchronous Z information and pair operations are seen and initiated in the
following GUI windows:
Pair Operation
RCU Operation
Usage Monitor
Script Operation
History
System Option
Menu commands for the pair operations that you can perform in the windows.
NOTE: Though LDKC#01 displays in the trees for some Continuous Access Synchronous Z windows,
it is not available for use in this version.
DescriptionContext menu commandWindow
Displays information about the pair, control unit (CU), data
path, pair status, and pair options.
Detailed InformationPair Operation window
Used to create new pairs.Add Pair
Used to release pairs.Delete Pair
Used to suspend pairs.Suspend Pair
Used to resynchronize pairs which are suspended.Resume Pair
Used to change the pair options.Change Pair Option
Displays remote system status and path status.RCU StatusRCU Operation
window