HP P9000 Business Continuity Manager User Guide
• YKQUERY
• YKRESYNC REVERSE
• YKEWAIT GOTO (DUPLEX)
5. From the local site, execute the YKRESYNC DELTAJNL command for the delta resync pair.
• YKQUERY
• YKRESYNC DELTAJNL
• YKEWAIT GOTO(DUPLEX)
If the command is successful, the Continuous Access Journal for Mainframe copy pair is
automatically moved to the HOLD status (delta resync pair).
6. Start primary site host maintenance.
Using a Delta Resync Configuration 311