HP P9000 Business Continuity Manager User Guide

Table 64 How to Prepare Configuration Files at Each Site (4x4x4 Cascade) (continued)
How to prepareContentsFile type
On the remote siteOn the intermediate
site
On the primary site
Not requiredNot requiredDefine a path set.A Primary -> Intermediate
inter-control unit logical
path
Path set definition file
Not requiredDefine a path set.Not required
An Intermediate ->
Primary inter-control unit
logical path
An Intermediate ->
Remote inter-disk
controller logical path
Define a path set.Not requiredNot requiredA Remote -> Intermediate
inter-disk controller logical
path
Not requiredNot requiredDefine a route list.A Primary -> Intermediate
-> Remote route/command
device
Route list definition
file/command device
definition file
Not requiredDefine a route list.Not required
An Intermediate ->
Primary route/command
device
An Intermediate ->
Remote route/command
device
Define a route list.Not requiredNot requiredA Remote -> Intermediate
-> Primary route/command
device
Transfer from the
primary site.
Transfer from the
primary site.
Define a copy group.A Continuous Access
Synchronous Z copy group
Copy group definition
file
Define a copy group.A Continuous Access
Journal Z copy group
Definition procedure (4x4x4 Cascade)
Basically, a 4x4x4 Cascade configuration is defined with the following procedure.
1. Set up the storage system.
Set the items that need to be set by using Remote Web Console from among the items listed
in Table 62 (page 204).
2. Set up a Business Continuity Manager environment.
Do the following:
Perform a Local Scan on the storage system at each site, and transfer the disk configuration
definition file containing the scan results of each site to all other sites.
On each site, define a path set and establish a logical path.
On each site, define a route list and register a command device.
3. Create copy groups.
On the primary site, define copy groups, create copy pairs, and register the copy pair in the
EXCTG of the storage system.
206 Configuration Definitions