HP P9000 Business Continuity Manager Release Notes (T5253-96056, September 2011)
Table 7 Restrictions (continued)
Restrictions#
Do not specify the following values to the DADID of a Disk Configuration Definition, a copy group and a route list.
Specifying those values may cause the information displayed in Discover HP Storage Arrays panel to become
incorrect.
6
• “R”
• “CMD”
• “I”
• “K”
• “RC”
Example that cannot be specified
• “R”
• “xx.R”
• “R.xx”
• “xx.R.xx”
where xx is an arbitrary string of one or more characters.
The following features cannot be used with P9500.
• 4x4x4 Cascade configuration
7
Specification differences from previous versions
This section describes the specification differences between V6.6 and V6.6.1 of BCM.
CLI commands
Table 8 Overall
VersionNew Specification in V6.6.1Specification in V6.6Item
6.6.1-00CAPACITY parameter is
available (default). When
NoneYKIMPORT
checks a volume, specify
CAPACITY (CHECK)
parameter. When not checks
volume, specify CAPACITY
(NOCHECK).
The capacity of volume
(cylinder) is obtained.
NoneYKQRYDEV
The capacity of volume
(cylinder) is obtained.
NoneYKSCAN
6 Fixes