error-action
Specifies the error action that is to be executed in the event that the action results in an error. If
this value is omitted, the error action specified in the ONACTIONERROR parameter in the YKMONOPT
file is executed.
Specifiable values are as follows:
STOP
Places the monitoring status of all copy groups specified in CGID in INACTIVE status.
SKIPONLY
Skips the cycle where an error occurred, but starts monitoring again from the next cycle.
EXIT(return-code) ~ <numeric characters> ((0 to 4095))
Stops BCM Monitor with the specified return code. HP recommends that you specify a value other
than 0, 4, 8, or 12 because these numbers are already used as BCM Monitor return codes.
When there are multiple copy pair statuses in a copy group
If there are multiple copy pair statuses in a copy group, one of the copy pair statuses is used as
the copy group status to be monitored. If there is a copy pair with one of the high priority levels
shown in the table below, that copy pair status is used for the copy group. For example, if there
are no copy pairs in the INVALID status, but there is a copy pair in the SUSPER status, then the
corresponding copy group is treated as being in the SUSPER status. If there are no copy pairs in
the INVALID or SUSPER status, but there is a copy pair in the NODELTA status, then the
corresponding copy group is treated as being in the NODELTA status.
Table 167 Copy Pair Status Priority
Copy pair statusPriority
INVALID1
CONSLOST2
SUSPER3
NODELTA4
HOLDER5
SUSPCU6
SIMPLEX7
PENDING8
TRANS9
HOLDTRNS10
REVRSY11
SUSPVS12
SUSPOP13
HOLD14
SWAPPING15
DUPLEX16
368 BCM Monitor Parameter Files