Table 148 (page 329) shows the Host-Discovered Array structure. The prefix for the name of the
Host-Discovered Array structure is one of the following:
When the YKLOAD command is used for creating the structure:
stem-name-specified-in-STEM-parameter and dad-id
When the YKSCAN command is used for creating the structure:
stem-name-specified-in-opSTEM-parameter Each REXX variable is preceded by a period (.).
Table 148 Host-Discovered Array Structure
DescriptionREXX variables
Last update IDUpdateIDSNnnnnn
Descriptions added by the userDescription
Storage system serial numberSerialNum
Storage system ModelModel
XP256
XP48 or XP512
XP128 or XP1024
XP10000 or XP12000
XP20000 or XP24000
P9500
Microcode numberMicrocode
Interface versionIFType
Physical DKC serial numberPhysicalSerialNum
1
Logical DKC numberLDKCNum
2
BC keyKey.BC
CA keyKey.CA
CAJ keyKey.CAJ
TCA keyKey.TCA
Non Gen'ed function flagNGDADIDEnable
0: Not a Non Gen'ed DAD ID
1: Non Gen'ed DAD ID
One of the storage system IDs of a
CU
SSIDCUxx
3
Device numberDevnCCAxx
4
Volume serial numberVolser
Storage system IDSSID
Volume capacity (the number of
cylinders)
Cyls
5
External volume informationExternal
6
Y: External volume
N: Not an external volume
About REXX Variable Structures 329