HP P9000 Business Continuity Manager Reference Guide (T5253-96058, September 2011)
Table Of Contents
- P9000 for Business Continuity Manager Software Reference Guide
- Contents
- 1 ISPF Panels
- Overview of ISPF Panels
- Common Displays Among Panels
- Main Menu Panel
- Installation Verification Summary Panel (Environment Settings Verification)
- Set Defaults Panel (Prefix and DAD ID Settings)
- Manage Licenses Panel (License Management)
- Discover/Define Configuration Panel (Configuration File Definition)
- Discover HP Storage System Panel
- Scan Device Address Extent Panel
- CU Selection List for Remote Storage Array Panel
- CCA Selection List for Edit devn Panel
- Edit Device Number for CU Panel
- Storage System/DADID Selection List Panel
- Control Unit Selection List Panel
- Command Control Address (CCA) Selection List Panel
- Scan Remote Device Address Extent Panel
- Route Config Panel
- Add Route List ID Panel
- Route Information Panel
- Add Route Panel
- Add APID Panel
- Inner Route Information Panel
- Add Route Entry Panel
- Add Remote Route Entry Panel
- Storage System Selection List Panel
- Define Command Device Panel
- Sort the Define Command Device Panel
- Edit APID Panel
- Entire Route Information Panel
- Add Route Entry Panel
- Storage System/DAD Selection List Panel
- Insert Route Entry Panel
- Edit Route Entry Panel
- Edit Remote Route Entry Panel
- Insert Remote Route Entry Panel
- Path Set Selection List Panel
- Copy Group Selection List Panel
- Add Copy Group Panel
- Copy Group Detail Definition Panel
- Copy Group Attributes Panel
- Setting C/T ID Attributes Panel
- Copy Group Pair Detail Panel
- Pair Selection List (Primary) Panel
- Import SMS Storage Group Panel
- Import SMS Storage Group Result Panel
- Pair Selection List (Secondary) Panel
- Sort Copy Group Container Panel
- Sort Copy Group Pairs List Panel
- Scan Copy Pair Inside Storage System Panel
- Browse Copy Group Detail Definition Panel
- Browse Copy Group Pair Detail Panel
- Discover HP Storage System Panel
- Manage Route Panel (Route Management)
- Manage Path Set Panel (Logical Path Management)
- Manage Copy Groups Panel (Copy Group Operation)
- Sort the Copy Groups Panel
- Executing YKLOAD
- Copy Group Status Summary Panel (Executing YKQUERY)
- Copy Group Storage System Summary Panel
- CAA Copy Group Performance Statistics Panel
- Sort CAA Copy Group Statistics Panel
- CAJ Copy Group Performance Statistics Panel
- Sort CAJ Copy Group Statistics Panel
- Copy Group Pair Status Panel
- Sort the Copy Group Pairs Status Panel
- Volume Query Information (BC) Panel
- Volume Query Information (CA) Panel
- Volume Query Information (CAA) Panel
- Volume Query Information (CAJ) Panel
- Volume Query Information Panel (Executing YKQRYDEV)
- Executing YKMAKE
- Executing YKSUSPND
- Executing YKRESYNC
- Executing YKDELETE
- Executing YKWATCH
- Executing YKEWAIT
- Executing YKRECVER
- Path Set Status of Copy Group Pair Panel (YKQRYDEV with PATH Parameter Specified)
- Logical Path Status of Copy Group Pair Panel
- Confirmation Panels
- Confirm Execution Dissolve Panel
- Confirm Execution Recover Panel
- Confirm Command Device Build Panel
- Confirm Cancellation of Changes Panel
- Confirm Cancellation of Editing Panel
- Confirm Command Device Delete Panel
- Confirm Configuration File Delete Panel
- Confirm Configuration File Update Panel
- Confirm Copy Group Load Panel
- Confirm Overwrite ONLINE Target Volume Panel
- Confirm Path Delete Panel
- Confirm Path Set Load Panel
- Confirm Route Delete Panel
- Confirm Route List Edit Panel
- Confirm Retry of Configuration File Create Panel
- Confirm Open/MF Consistency Group Suspension Panel
- 2 CLI Commands
- Copy Types and Targets for Which Commands Can Be Executed
- List of Functions
- Configuration Files That Must Be Loaded Before Command Execution
- Command details
- YKBLDCMD Command
- YKBLDPTH Command
- YKCONMSG Command
- YKDELCMD Command
- YKDELETE Command
- YKDELPTH Command
- YKDROP Command
- YKENV Command
- YKERCODE Command
- YKEWAIT Command
- YKEXPORT Command
- YKFCSTAT Command
- YKFREEZE Command
- YKH2B Command
- YKIMPORT Command
- YKINSCHK Command
- YKLOAD Command
- YKMAKE Command
- YKQHPATH Command
- YKQRYDEV Command
- YKQRYPTH Command
- YKQUERY Command
- YKRECVER Command
- YKRESYNC Command
- YKRUN Command
- YKSCAN Command
- YKSLEEP Command
- YKSTATS Command
- YKSTORE Command
- YKSUSPND Command
- YKWATCH Command
- YKWTOMSG Command
- CLI Command Coding Examples
- 3 Data Objects
- Saving and Converting Objects
- Dataset Formats and Required Disk Capacity for the Configuration File
- XML Document Type Definitions
- Configuration File Examples
- About REXX Variable Structures
- REXX Variables Updated by YKQUERY and YKEWAIT Commands
- CSV Files Used by the Copy Group Definition File Generation Function
- 4 BCM Monitor Parameter Files
- 5 Support and other resources
- A Example of the Scan Results of PPRC Copy Pairs
- B Symbols Used in Syntax Explanations
- C Acronyms and Abbreviations
- Glossary
- Index
The S-VOL can be read or written even when data is being copied. When this parameter is not
specified, the S-VOL can be read or written after data copying, and transition to the SUSPOP status
have finished. For details on what happens when the ATTIME parameter is specified for the NORMAL
ATTIME suspend function, see the HP StorageWorks P9000 Business Copy for Mainframe Systems
User Guide: HP XP24000 Disk Array, HP XP20000 Disk Array or the HP StorageWorks P9000
Business Copy for z/OS User Guide: HP XP12000 Disk Array, HP XP10000 Disk Array, HP 200
Storage Virtualization System. When the CAJ ATTIME suspend function is used, the method of
performing suspensions used depends on the specified ATOPT parameter.
FORWARD
Applies to Continuous Access Synchronous for Mainframe, Continuous Access Asynchronous for
Mainframe, and Continuous Access Journal for Mainframe.
When the copy direction is forward Places copy pairs in the SUSPOP status, so that the copy
direction goes from the primary site to the secondary site
after RESYNC. If this parameter is specified for Continuous
Access Asynchronous for Mainframe, the data
synchronization method during the suspension will be the
same as that used when the DRAIN parameter is specified.
If this parameter is specified for Continuous Access Journal
for Mainframe, the data synchronization method during the
suspension will be the same as that used when the FLUSH
parameter is specified.
When the copy direction is reverse Places copy pairs in the SWAPPING status, so that the copy
direction goes from the primary site to the secondary site
after RESYNC. If this parameter is specified for Continuous
Access Asynchronous for Mainframe or Continuous Access
Journal for Mainframe, the data synchronization method
during the suspension will be the same as that used when
the FLUSH parameter is specified.
REVERSE
Applies to Continuous Access Synchronous for Mainframe, Continuous Access Asynchronous for
Mainframe, and Continuous Access Journal for Mainframe.
When the copy direction is forward Places copy pairs in the SWAPPING status, so that the copy
direction goes from the secondary site to the primary site
after RESYNC. If this parameter is specified for Continuous
Access Asynchronous for Mainframe or Continuous Access
Journal for Mainframe, the data synchronization method
during the suspension will be the same as that used when
the FLUSH parameter is specified.
When the copy direction is reverse Places copy pairs in the SUSPOP status, so that the copy
direction goes from the secondary site to the primary site
after RESYNC. If this parameter is specified for Continuous
Access Asynchronous for Mainframe, the data
synchronization method during the suspension will be the
same as that used when the DRAIN parameter is specified.
If this parameter is specified for Continuous Access Journal
for Mainframe, the data synchronization method during the
suspension will be the same as that used when the FLUSH
parameter is specified.
When neither FORWARD parameter nor REVERSE parameter are specified, the status of copy pairs
become SUSPOP. The copy direction is not changed at the time of RESYNC.
Command details 253