HP P9000 Business Continuity Manager Reference Guide (T5253-96058, September 2011)

Table Of Contents
NEWGROUP(copy-group-ID) ~ < GROUP string>
Specify a name for the copy group definition file that is to be created, without the prefix.GRP part.
Maximum length that can be specified = 44 - (5 + PREFIX-length)
A new copy group definition file is created under the name specified in this parameter. To overwrite
an existing copy group definition file, specify the same name in the BASEGROUP and NEWGROUP
parameters.
CAPACITY({CHECK|NOCHECK})
Specify whether to check the capacities of the P-VOL and S-VOL for the newly defined copy pair.
The default is CHECK.
CHECK
Checks whether the capacities of the P-VOL and S-VOL of the defined copy pair match.
NOCHECK
Does not check whether the capacities of the P-VOL and S-VOL of the defined copy pair match.
Specify this parameter when defining a copy pair for migration whose P-VOL and S-VOL capacities
are different.
Return Codes
Table 118 (page 217) lists the return codes to be returned when the YKIMPORT command terminates.
Table 118 YKIMPORT Command Return Code List
MeaningReturn Code
The command terminated completed normally. A copy group definition file was
created.
0
No copy pairs were defined in the specified CSV file. No data was output to the
copy group definition file.
4
A copy group definition file was created, but a problem was detected.8
Possible causes are as follows:
There was an inconsistency in the input information.
An attempt to check the capacities failed because the capacity of the P-VOL,
S-VOL, or both volumes could not be acquired.
The input file was invalid.32
An error occurred during file I/O processing.40
Termination due to invalid parameters.48
An error occurred during REXX processing.64
YKINSCHK Command
Format
YKINSCHK
Function
This command is a TSO/E command called from REXX scripts.
This command verifies whether the settings required during an installation and setup have been
specified correctly. Then, this command outputs a verification-result message and the setting
information to the TSO/E panel.
Command details 217