HP P9000 Business Continuity Manager Reference Guide (T5253-96058, September 2011)

Table Of Contents
After specifying the copy pair to operate, to view REXX variables (such as SimplexCt) shown in
information for copy pairs that are not operation targets, execute the YKQUERY command or
YKEWAIT command for all copy pairs.
TO({PRIMARY|SECONDARY})
Applies to Continuous Access Synchronous for Mainframe, Continuous Access Synchronous for
Mainframe with the HyperSwap attribute, Continuous Access Asynchronous for Mainframe, and
Continuous Access Journal for Mainframe.
Specify this parameter to monitor copy groups by monitoring the status of either P-VOLs or S-VOLs.
When the TO parameter is specified, the copy group container is not checked for EXCTG registration
information.
PRIMARY
Monitors the status of P-VOL during copy group definition.
SECONDARY
Monitors the status of S-VOL during copy group definition.
VOLUNIT
Usually, information is obtained for each CU, but when this parameter is specified, information is
obtained for each volume.
Return Codes
Table 113 (page 209) lists the return codes to be returned when the YKEWAIT command terminates.
Table 113 YKEWAIT Command Return Code List
MeaningReturn Code
The command terminated abnormally, possibly because the user SVC routine has
not been included properly.
-4095 to -4040
The module cannot be loaded. Possible causes are as follows:-3
The library dataset has not been linked.
The module is protected by the RACF program control function.
An interruption occurred during execution.-1
The command completed normally.0
The timeout interval expired before the group status changed to the requested group
status. For CG containers specified by EXCTG ID, a timeout occurred before all
journal groups were registered in EXCTG.
1
4
Unexpected transition of group status.8
Command details 209