HP P9000 Business Continuity Manager Reference Guide (T5253-96058, September 2011)

Table Of Contents
SCU(cu-number) ~ <2-digit hexadecimal number>
If this parameter is specified, for each logical path within the path set stored in the path set structure
specified for the STEM parameter, inter-CU logical paths will be established such that the CU
number of the RCU matches the value specified for this parameter. Inter-DKC logical paths are not
affected by this parameter.
If neither this parameter nor any other parameters are specified, the command establishes all
inter-CU logical paths.
{FORWARD|REVERSE}
Specify the direction in which the logical path is to be established.
If neither is specified, the command will establish a bidirectional logical path.
FORWARD
The command establishes the logical paths that are identified in the path set stored in the path set
structure specified by the STEM parameter. Each path extends from the initiator node defined by
stem-name-specified-in-STEM-parameterPATH.n.Pri to the target node defined by
stem-name-specified-in-STEM-parameterPATH.n.Sec, in the forward direction.
REVERSE
The command establishes the logical paths that are identified in the path set stored in the path set
structure specified by the STEM parameter. Each path extends from the initiator node defined by
stem-name-specified-in-STEM-parameterPATH.n.Sec to the target node defined by
stem-name-specified-in-STEM-parameterPATH.n.Pri, in the reverse direction.
TYPE({CU|DKC})
This parameter specifies the type (inter-CU logical path or inter-DKC logical path) of the logical
path to be established.
If neither this parameter nor any other parameters are specified, the command establishes all
logical paths.
CU
Out of the logical paths within the path set stored in the path set structure specified by the STEM
parameter, the logical paths that have CU set for
stem-name-specified-in-STEM-parameterPATH.n.type are established.
DKC
Out of the logical paths within the path set stored in the path set structure specified by the STEM
parameter, the logical paths that have DKC set for
stem-name-specified-in-STEM-parameterPATH.n.type are established.
NOTE:
Before executing the command, create and load the path set definition file.
If a message that contains sense information for the storage system is output, see the list of
error codes in the HP StorageWorks P9000 for Business Continuity Manager Messages and
then eliminate the cause of the error. Alternatively, in the Edit Logical Path Definition panel,
specify a different, valid volume on which a device scan has been performed, in CU, SSID,
and CCA in the path set definition file for the command execution target.
If all of the volumes in the CU are Non Gen'ed volumes, load the route list before executing
the command.
Command details 191