HP P9000 Business Continuity Manager Reference Guide (T5253-96058, September 2011)

Table Of Contents
Table 82 Contents of the Volume Query Information (CAA) Panel (continued)
DescriptionItem
On the second line:
(LOCAL):
ATTIME-suspend-time-in-local-time
Format of the ATTIME
suspend time: YYYYMMDD
HH:MM :SS.NNNNNN
YYYY: The year is
displayed.
MM: The month is
displayed.
DD: The date is
displayed.
HH: The hour is
displayed.
MM: The minute is
displayed.
SS.NNNNNN: The
second is displayed.
Consistency timeConsistency Time (GMT)
If the consistency time is
invalid, N/A is displayed.
Consistency group IDC/T ID
Error level
4
ERROR LVL
VOLUME: When a failure
occurs, only the affected
volumes are suspended.
GROUP: When a failure
occurs, all volumes in the
same copy group are
suspended.
C/T group timer type
4
TIMER TYPE
SYSTEM: Uses a
timestamp to maintain
consistency.
LOCAL: Uses the storage
system's internal clock to
maintain consistency.
NONE: Does not maintain
consistency.
Write-protect for the S-VOL
4
PROT MODE
PROTECT: Update of the
S-VOL is prohibited after
the copy pair is
suspended (YKSUSPND
command is executed).
PERMIT: Update of the
S-VOL is allowed after the
copy pair is suspended
(YKSUSPND command is
executed).
Manage Copy Groups Panel (Copy Group Operation) 145