Table 82 Contents of the Volume Query Information (CAA) Panel (continued)
DescriptionItem
Always displays > when the
Status of the Primary Volume
is SIMPLEX.
Storage system serial
number of the S-VOL at
definition
SNSecondary Volume
SSID of the S-VOL at
definition
SSID
CU number of the S-VOL at
definition
CU
CCA of the S-VOL at
definition
CCA
Device number of the S-VOL
at definition
DEVN
The following volume online
information is displayed to
the right of DEVN:
1
*: Online
-: Offline
Nothing is displayed when
volume online information
cannot be obtained.
Copy pair status
2
Status
JOURNAL is displayed for
the journal volume.
3
ATTIME suspend time and
ATTIME suspend status
Suspend ATTIME
On the first line (GMT) :
ATTIME-suspend-time-in-GMT
- status is displayed.
For
ATTIME-suspend-time-in-GMT
- ATTIME-suspend-status,
one of the following is
message displayed:
Notset: ATTIME
suspend time is not set.
ATTIME-suspend-time
-WAITING: ATTIME
suspend has not been
executed.
ATTIME-suspend-time
-TIMESTAMP
TRIGGERED: A
suspension was
performed at
ATTIME-suspend-time.
ATTIME-suspend-time
-TIMEOUT TRIGGERED
A suspension was
performed due to a
timeout.
144 ISPF Panels