HP P9000 Business Continuity Manager Reference Guide (T5253-96058, September 2011)

Table Of Contents
device information reported by the storage system is displayed in the Pair Volume column. If MISMATCH is displayed,
check the configuration file used, as well as the actual storage system configuration information and settings.
NOTE: In the following cases, N/A is displayed for the device information.
When the YKQRYDEV command returns an error
When displaying information about a device of a remote storage system if the route list has
not been loaded or the target storage system is not included in the route list
Volume Query Information (CAA) Panel
If you specify q in AC on the Copy Group Pair Status panel, the YKQRYDEV command is executed
on the P-VOL and S-VOL, and the Volume Query Information (CAA) panel is displayed for a CAA
copy pair.
Figure 114 (page 142) and Figure 115 (page 143) show a configuration example and the Volume
Query Information (CAA) panel displayed in this configuration.
Figure 114 Volume Query Configuration Example (Cnt Ac-A Z)
142 ISPF Panels