P9000Info v22.00.00 Release Notes (T1789-96326, August 2011)

NOTE:
Multipathing is enabled.
Firmware requirements
Table 1 lists the minimum firmware requirements.
Table 1 Firmware requirements
Minimum RequirementXP/ P9000 Array
60.01.31.00/00XP24000
60.01.66.00/00XP20000
50.07.69.00/00SVS200
50.09.34.00/00XP12000
50.09.34.00/00XP10000
21.14.30.00/00XP128, XP1024
01.19.99.00/02XP48
70-01-26-00/00 or laterP9500
V1.15.03 or later
P9000/XP RAID Manager Library (RMLIB) (P9000,
XP24000, XP12000, XP10000, and SVS200)
Enhancements
P9000Info shows the following additional fields for LDEVs belonging to THP volumes if -X option is
used:
Pool Id
Total Pool Capacity
Used Pool Capacity
Fixes
P9000Info 22.00.00 includes fix for the following:
xpinfo -e does not display the LUN H/W paths on HPUX 11.31.
On Solaris platform when persistent binding is used in fabric topology, that is when a SCSI target
ID is bound to a particular WWN, xpinfo does not show output for those devices.