P9000Info v21.00.00 Release Notes (T1789-96320, May 2011)

NOTE:
Multipathing is enabled.
Firmware requirements
Table 1 lists the minimum firmware requirements.
Table 1 Firmware requirements
Minimum RequirementXP/ P9000 Array
60.01.31.00/00XP24000
60.01.66.00/00XP20000
50.07.69.00/00SVS200
50.09.34.00/00XP12000
50.09.34.00/00XP10000
21.14.30.00/00XP128, XP1024
01.19.99.00/02XP48
70-01-26-00/00 or laterP9500
V1.15.03 or later
P9000/XP RAID Manager Library (RMLIB) (P9000,
XP24000, XP12000, XP10000, and SVS200)
Enhancements
None.
Fixes
P9000Info 21.01.00 includes fixes for the following:
P9000Info does not work for a P9500 Disk Array that is configured with RAID groups greater
than 18-1.
P9000Info gives incorrect array serial number, if the serial number of P9500 Disk Array is greater
than 65535.
On a HP-UX v11.31 host, P9000Info does not support Cluster Device File System (CDSF). So, the
output of P9000Info does not include the mapping of each LUN to the volume group and mount
points.
Notes
If you are using P9000 Performance Advisor Solaris, AIX or HP-UX host agent, view the SLPR and
CLPR information for your XP disk arrays through P9000 Performance Advisor, as P9000Info for these
4