HP XP P9000 Performance Advisor v5.5 Software Troubleshooting and FAQs Guide (T1789-96344, February 2013)

1. Inspect the <MachineName>_<timestamp>_OraclePatch.log file.
2. Ensure that the OPatch folder located under %PADB_HOME%\ora_db\OPatch is not open
in windows explorer or not pointed to by a command prompt.
3. Ensure that the following services relevant for Oracle patch installation are stopped and no
applications are accessing any files pointed to by %PADB_HOME% environment variable.
Distributed Transaction Co-ordinator
HP XP P9000 Performance Advisor Database
HP XP P9000 Performance Advisor Database Job Scheduler
HP XP P9000 Performance Advisor Database Listener
HP XP P9000 Performance Advisor Database VSS Writer
HP XP P9000 Performance Advisor Monitor
HP XP P9000 Performance Advisor Security
HP XP P9000 Performance Advisor Tomcat
The Oracle patch application process for HP XP P9000 Performance Advisor Software failed. For
more information, inspect the <MachineName>_<timestamp>_OraclePatch.log located
under <directory name> and opatch<timestamp>.log located under <directory
name>. The installation wizard will exit now.
It indicates that the patch operation on binaries under %PADB_HOME%\ora_db failed.
Resolution: Inspect the <MachineName>_<timestamp>_OraclePatch.log and
opatch<timestamp>.log files. For further assistance to resolve the issue, contact your HP
Support representative along with the log files.
There were errors encountered during the execution of post upgrade scripts. For more information,
inspect the log file: catbundle_WINBUNDLE_PADB_APPLY_<timestamp>.log located under
<directory name> and the <MachineName>_<timestamp>_OraclePatch.log located
under <directory name>.
After the patch is applied on database binaries, few SQL scripts are executed on the PADB. If the
operation fails, the error message is displayed.
Resolution: Inspect the catbundle_WINBUNDLE_PADB_APPLY_<timestamp>.log and
<MachineName>_<timestamp>_OraclePatch.log files. For further assistance to resolve the
issue, contact your HP Support representative along with the log files.
HP XP P9000Watch issues
This section describes the troubleshooting scenarios for HP XP P9000Watch.
Array type not seen in HP XP P9000Watch
Cause
If the array type for a particular DKC serial number is not displayed in HP XP P9000Watch, it
might be due to the command device being non-functional or not created.
Resolution
To verify, run getxpperf with the command device name.
For example: ./getxpperf /dev/rdisk/c0d0t1, where /dev/rdisk/c0d0t1 is the command
device name.
For Windows host agent, the getxpperf tool is present in the <Installation_directory>:\
xppa\hostagent\sbin folder.
For non-Windows host agent, the getxpperf tool is present in the \opt\xppa\hostagent\
sbin folder.
HP XP P9000Watch issues 35