HP XP P9000 Performance Advisor Software v6.0 Release Notes

When a manual purge or data archival process is active, occasionally, you might notice that
the management station overlooks data samples received from the host agents.
The purging may take hours to complete based on the database size. HP recommends that
you stop the performance collection before starting the purge to overcome missing data points
during purge.
Current Status—This will be fixed in the subsequent release.
For XP/P9500 disk arrays with concatenated parity groups, you might notice 4D+4D RAID
type instead of two 2D+2D concatenated parity groups in the Performance Estimator screen.
Current Status—Fix is being investigated, no ETA as of P9000 Performance Advisor v6.0
release date.
While charting backend transfer metrics for DKAs or ACPs with concatenated RAID groups,
you might observe that the total write tracks do not match the sum of the individual DKA or
ACP metrics.
Current Status—This will be fixed in the subsequent release.
An error log is displayed on the console of the AIX host agent in the following conditions:
HP XP P9000Watch is active on Advanced Interactive eXecutive (AIX) v6.1.
Multi-pathing (MPIO) is enabled on the AIX host agent.
Parameters, dyntrk is set to yes and fc_error is set to fast_fail.
The error log is also displayed when you run the errpt a command from the Kernel of the
AIX operating system. The following is an excerpt from the error log:
LABEL: FSCSI_ERR10IDENTIFIER: 1FB4FD21Date/Time: Mon Aug 10 15:03:51 CDT
2009Sequence Number: 269527
You can ignore the error log, as it does not impact the HP XP P9000Watch activities or the
output it provides.
Current Status—Fix is being investigated, no ETA as of P9000 Performance Advisor v6.0
release date.
HP XP P9000Watch does not support apostrophe (') in the host group name.
Current Status—Fix is being investigated, no ETA as of P9000 Performance Advisor v6.0
release date.
When you uninstall P9000 Performance Advisor on a management station, the contents in
the C:\windows\system32\config\Oracle directory does not get removed. Hence,
re-installation fails.
Workaround—Delete the C:\windows\system32\config\Oracle directory before
re-installing P9000 Performance Advisor on the management station.
Current Status—If you execute Install Assist utility, an error is displayed.
When you select All Report type, HP recommends that you should use one of the following
formats: PDF, HTML, or Docx over the RTF format.
Current Status—Fix is being investigated, no ETA as of P9000 Performance Advisor v6.0
release date.
The HP XP P9000Watch Linux x86_64 binary is meant only for RHEL 6.1 x86_64. For all
other Linux x86_64 distributions, use HP XP P9000Watch Linux binary.
Current Status—Fix is being investigated, no ETA as of P9000 Performance Advisor v6.0
release date.
Notes 7