HP StorageWorks P9000 Performance Advisor Software v5.4.1 Release Notes (T1789-96345, October 2012)

The P9000Watch Linux x86_64 binary is meant only for RHEL 6.1 x86_64. For all other Linux
x86_64 distributions, use P9000Watch Linux binary.
Current Status: Fix is being investigated, no ETA as of P9000 Performance Advisor v5.4.1
release date.
If Apex controller is already installed, then stop the Apex controller service before installing
or upgrading P9000 Performance Advisor HA.
Current Status: Fix is being investigated, no ETA as of P9000 Performance Advisor v5.4.1
release date.
P9000 Performance Advisor installation is not supported on domain controller in Windows
Vista, Windows Server 2008, Windows Server 2008 R2, and Windows 7 platforms.
Current Status: Fix is being investigated, no ETA as of P9000 Performance Advisor v5.4.1
release date.
In P9000Watch, the CA Journal, CA Sync/Async Metrics are not available in CLI mode.
Current Status: Fix is being investigated, no ETA as of P9000 Performance Advisor v5.4.1
release date.
You cannot plot multiple charts simultaneously at the Custom Group level charts. You must
plot one chart at a time.
Current Status: Fix is being investigated, no ETA as of P9000 Performance Advisor v5.4.1
release date.
P9000Watch does not support THP Pool, Smart Pool, BC, Snapshots, and External RG’s.
Current Status: This will be fixed in the subsequent release.
Custom report does not display CHIP chart details.
Workaround: Generate CHIP report separately. Do not include it with any other custom report.
Current Status: Fix is being investigated, no ETA as of P9000 Performance Advisor v5.4.1
release date.
If Host is not displayed under Host information screen post Host agent Installation on SLES 11
SP1, refer HostDebugOut.log placed under /opt/xppa/hostagent/log.
If it displays the following error, install compat-32bit-XXX.rpm to resolve the third party
software issue:
Exception in thread "Thread-1" java.lang.UnsatisfiedLinkError:
/opt/xppa/hostagent/lib/libBccaRaidMgrLibJNI.so: libstdc++-libc6.2-2.so.3: cannot open
shared object file: No such file or directory
Current Status: no ETA as of P9000 Performance Advisor v5.4.1 release date.
When you create an alarm and attempt to set multiple destination email addresses for it,
P9000 Performance Advisor Alarm screen displays an error message “Please Enter a valid
Email address.
Workaround: Create an alias email address, for example, xyz-abc@hp.com and add the
required email address(s) such as xyz@hp.com and abc@hp.com to this alias email address.
In P9000 Performance Advisor Alarm screen, you must specify the alias email address
(xyz-abc@hp.com) in the Email Destination field. This sends the emails to the destination
email addresses (xyz@hp.com and abc@hp.com), when an alarm is triggered.
NOTE: The email address(s) included in an alias email address must belong to the same
domain.
Current Status: This will be fixed in the subsequent release.
8 HP StorageWorks P9000 Performance Advisor Software v5.4.1 Release Notes