HP StorageWorks P9000 Performance Advisor Software v5.4.1 Release Notes (T1789-96345, October 2012)
• The P9000Watch Linux x86_64 binary is meant only for RHEL 6.1 x86_64. For all other Linux
x86_64 distributions, use P9000Watch Linux binary.
Current Status: Fix is being investigated, no ETA as of P9000 Performance Advisor v5.4.1
release date.
• If Apex controller is already installed, then stop the Apex controller service before installing
or upgrading P9000 Performance Advisor HA.
Current Status: Fix is being investigated, no ETA as of P9000 Performance Advisor v5.4.1
release date.
• P9000 Performance Advisor installation is not supported on domain controller in Windows
Vista, Windows Server 2008, Windows Server 2008 R2, and Windows 7 platforms.
Current Status: Fix is being investigated, no ETA as of P9000 Performance Advisor v5.4.1
release date.
• In P9000Watch, the CA Journal, CA Sync/Async Metrics are not available in CLI mode.
Current Status: Fix is being investigated, no ETA as of P9000 Performance Advisor v5.4.1
release date.
• You cannot plot multiple charts simultaneously at the Custom Group level charts. You must
plot one chart at a time.
Current Status: Fix is being investigated, no ETA as of P9000 Performance Advisor v5.4.1
release date.
• P9000Watch does not support THP Pool, Smart Pool, BC, Snapshots, and External RG’s.
Current Status: This will be fixed in the subsequent release.
• Custom report does not display CHIP chart details.
Workaround: Generate CHIP report separately. Do not include it with any other custom report.
Current Status: Fix is being investigated, no ETA as of P9000 Performance Advisor v5.4.1
release date.
• If Host is not displayed under Host information screen post Host agent Installation on SLES 11
SP1, refer HostDebugOut.log placed under /opt/xppa/hostagent/log.
If it displays the following error, install compat-32bit-XXX.rpm to resolve the third party
software issue:
Exception in thread "Thread-1" java.lang.UnsatisfiedLinkError:
/opt/xppa/hostagent/lib/libBccaRaidMgrLibJNI.so: libstdc++-libc6.2-2.so.3: cannot open
shared object file: No such file or directory
Current Status: no ETA as of P9000 Performance Advisor v5.4.1 release date.
• When you create an alarm and attempt to set multiple destination email addresses for it,
P9000 Performance Advisor Alarm screen displays an error message “Please Enter a valid
Email address”.
Workaround: Create an alias email address, for example, xyz-abc@hp.com and add the
required email address(s) such as xyz@hp.com and abc@hp.com to this alias email address.
In P9000 Performance Advisor Alarm screen, you must specify the alias email address
(xyz-abc@hp.com) in the Email Destination field. This sends the emails to the destination
email addresses (xyz@hp.com and abc@hp.com), when an alarm is triggered.
NOTE: The email address(s) included in an alias email address must belong to the same
domain.
Current Status: This will be fixed in the subsequent release.
8 HP StorageWorks P9000 Performance Advisor Software v5.4.1 Release Notes