HP StorageWorks P9000 Performance Advisor Software v5.4.1 Release Notes (T1789-96345, October 2012)

Fixes
P9000 Performance Advisor v5.4.1 includes the following fixes:
Performance Advisor GUI accepts multiple e-mail addresses for Test SMTP and Alarm related
e-mails from the configuration alarm screen.
Serious alarms and good information alarms are functional.
Alarm triggers after editing or updating the alarms.
Updated changes for alarms are seen in alarm history.
Notes
The log file PA_PATCH.log for the v5.4.1 patch is located in the temp folder.
Repair and Modify functions are not available in the v5.4.1 patch installer; only uninstall
option is available through the Add or Remove Programs menu item.
If RAID6 with 14D+2P disk mechs are configured in an array, the configuration collection
and performance collection continues to be functional; however, the disk mechs displayed
under the Array View screen for 14D+2P is incorrect.
Occasionally, the recovery alarms do not dispatch if the configured value for the metric is
zero.
P9000Watch and CLUI are not supported on an OpenVMS Integrity Server (IA-64) host.
Current Status: Fix is being investigated, no ETA as of P9000 Performance Advisor v5.4.1
release date.
The Show the Windows Installer Log check box is non-functional.
Workaround: To view the PA_Install.log file, go to <system_drive>:\
P9000_PA_Install_Log path, where <system_drive> refers to the drive on which the
operating system is installed.
Current Status: Fix is being investigated, no ETA as of P9000 Performance Advisor v5.4.1
release date.
The Journal Group Detail View screen does not display data when you click a journal group
volume ID that is created from concatenated RAID groups.
Workaround: In the Array View - LDEV screen, filter the existing list of LDEV records for a
particular journal pool ID to view LDEVs that belong to that particular journal pool. The LDEV
related performance metrics are also displayed.
Current Status: This will be fixed in the subsequent release.
The following Cache related metrics are not displayed for selection in the Choose Metrics box
when you select the Cache node for an XP1024/128 Disk Array under Charts:
Cache Usage MB
Cache Usage Util
Cache Write Pending MB
Cache Side File Usage MB
Cache Write Pending Util
Cache Side File Usage Util
Workaround: View the Cache related metrics for an XP1024/128 Disk Array on the
Performance View and Summary View screens.
Fixes 5