HP StorageWorks P9000 Performance Advisor Software v5.4 Install Guide (T1789-96330, April 2012)
The following indicates that both the Windows host agent and real-time services have restarted:
Restarting HP StorageWorks P9000 Performance
Advisor Host Agent service
Stopping HP StorageWorks P9000 Performance Advisor
Host Agent service, please wait...
Starting HP StorageWorks P9000 Performance Advisor
Host Agent service, please wait…
Restarting HP StorageWorks P9000 Performance Advisor
Realtime service
Stopping HP StorageWorks P9000 Performance Advisor
Realtime service, please wait…
Starting HP StorageWorks P9000 Performance Advisor
Realtime service, please wait...
To restart the UNIX host agent and real-time services:
• To restart the HP StorageWorks P9000 Performance Advisor Hostagent service, type /opt/xppa/
hostagent/sbin/xppa restart in the command prompt window.
• To restart the HP StorageWorks P9000 Performance Advisor Realtime Server service, type /opt/
xppa/realtime/xpparealtime restart in the command prompt window.