HP StorageWorks P9000 Performance Advisor Software v5.3 User and Troubleshooting Guide (T1789-96322, August 2011)

In the above image, under Front-end for the P9000 disk array 53046:
1. Front-end is the main category.
2. Port is the component type. The number (32) indicates the number of ports for P9500 Disk Array
53046.
3. CL1A is one of the individual ports.
4. CHA1EU is an individual CHA associated with the port CL1A.
The related metrics associated with the component types and the individual components in the Front-end
category are displayed in the Choose Metrics box. Select the metrics at the component type or the
individual component levels, or both to view the related performance graphs in the Chart Work Area.
For a description of these metrics, see Metric Category, metrics, and descriptions on page 441.
The following table provides the default set of metrics that are displayed in the Choose Metrics box
for the XP and the P9000 disk arrays. The Yes and No under For the XP disk arrays and For the
P9000 disk arrays columns indicate whether the particular default metric is applicable for that XP or
P9000 disk array.
For P9000 disk arraysFor XP disk arraysDefault set of metricsFront-end category
YesYes
Maximum Port IO/s Fron-
tend
Maximum Port MB/s
Frontend
Front-end
YesYes
Maximum Port IO/s Fron-
tend
Maximum Port MB/s
Frontend
Port
NoYesCHIP MP UtilMP
NoYesCHIP Util TotalCHA
Using charts274