HP XP P9000 Tiered Storage Manager Software 7.6.1-02 Release Notes (TB585-96039, March 2014)
Table Of Contents
- HP XP P9000 Tiered Storage Manager Software 7.6.1-02 Release Notes
- Description
- Product models
- Devices supported
- Operating systems
- Enhancements
- Fixes
- Important considerations
- Filter conditions in the Create Tier dialog box and the Edit Tier dialog box
- Upgrading HP XP P9000 Command View Advanced Edition from 7.4.1 or earlier (in Windows)
- Temporary shortcut folder after installation or removal (in Windows)
- Specifying is not or <> in filter conditions
- Executing the GetFreeSpaces command for an SMI-S Enabled storage system
- Delay displaying the volume list when creating a Data Placement Profile
- Deletion of the logical group with data placement profiles
- Manage Data Placement Profiles (Logical Group View) dialog box
- Estimated time for the search inconsistency task (search inconsistent data placement profile task)
- Storage system links in the Mobility tab
- Migrating Mainframe THP volumes
- A tier created from the Device Manager GUI is not displayed in Tiered Storage Manager
- Editing a storage tier created by the CLI in the Edit Tier dialog box
- Message about refreshing the storage domain
- Mozilla 1.7.13 (HP-UX 11i v3) support
- Monitoring schedule templates
- Referencing (viewing) data migration tasks in Legacy mode
- Starting the migration wizard
- When an unexpected error (KAIC16009-E) occurs in the Migrate Data dialog box
- Executing a migration task in Legacy mode or by the Tiered Storage Manger CLI
- Data migration by using volumes that are applied data placement profiles
- Estimated time for data placement profile operations
- Stopping search inconsistency task (search inconsistent data placement profile task)
- Performance analysis
- Using XP P9000 Tiered Storage Manager CLI in a firewall environment
- Executing data migration
- KAIC05607-E or KAIC06400-E error during Migrate Data operation
- Selecting a tier when creating a migration plan
- Prerequisites
- Installation instructions
- Compatibility/interoperability
- Revision information
- Device Manager Software 7.6.1-02
- Replication Manager Software 7.6.1-02
- Tiered Storage Manager Software 7.6.1-02
The supported storage system is HP XP P9500 Storage.
• In the Tiered Storage Manager GUI, the trend chart can now be displayed. This chart contains
capacity and performance information for the THP/Smart pool.
The following data is displayed in the trend chart:
◦ THP/Smart pool
Capacity Usage–
– Average Input IOPS
– Average Output IOPS
◦ Smart pool Tier
Capacity Usage–
– Average IOPS Utilization
The supported storage system is HP XP P9500 Storage.
The capacity and performance information in the trend chart can be exported in a CSV format.
• In the Tiered Storage Manager GUI, you can now check the performance and capacity of the
Smart pools that are displayed in "Top10: Tiers with the Highest Performance Utilization".
The supported storage system is HP XP P9500 Storage.
Fixes
The following issue was resolved in 7.6.1-02:
• Even if a volume met conditions for a migration source volume, the volume was displayed as a
volume that was not usable for migration source volume, and the restriction reason did not appear.
Important considerations
Filter conditions in the Create Tier dialog box and the Edit Tier dialog box
When you use the Create Tier dialog box or the Edit Tier dialog box, sometimes the filter conditions
cannot be saved, and the following issues might occur:
• The KAIC15231-E message is displayed in the GUI, and tiers cannot be created.
• The KAIC15239-E message is displayed in the GUI, and tiers cannot be edited.
• The KATS50201-E and KATS61103-E* messages are displayed for the CreateStorageTier
command, and tiers cannot be created.
• The KATS50221-E and KATS61103-E* messages are displayed for the ModifyStorageTier
command, and tiers cannot be edited.
*The KAIC03016-E message is displayed in the KATS61103-E message.
If an error occurs, shorten the character length of the filter condition.
To save a filter condition that uses two-byte characters in the name, enter the two-byte characters (no
more than 16 characters) in the Edit Storage Systems dialog box.
Upgrading HP XP P9000 Command View Advanced Edition from 7.4.1 or earlier (in
Windows)
In an environment where Host Data Collector (for Windows) version 7.4.1 or earlier is installed, the
Fatal Application Error dialog box might appear during an upgrade installation of HP XP P9000
Command View Advanced Edition. If this dialog box appears, click OK to ignore it and to continue
4 Fixes