HP P9000 Command View Advanced Edition Software Mainframe Agent Installation and Configuration Guide
Explanation and actionsMessage textMessage ID
P9000 mainframe agent failed to complete the requested
processing. P9000 mainframe agent might not support this
device. Processing will continue with this device skipped.
Check the status of the device involving the error, correct
any errors related to the configuration or execution
conditions, and then re-execute the command.
device-number-1 (string)
The device that issued I/O
device-number-2 (string)
The device to be manipulated
code1 (Hexadecimal number)
Message type
code2 (Hexadecimal number)
Reason code
code3 (Hexadecimal number)
Error code (Maintenance information)
code4 (Hexadecimal number)
Subcommand code
xxx (decimal number)
Command code of the command that was executing
when the error occurred
See the command code description in the explanation
of the YKZ201E message.
yyy (string)
Maintenance information
DASD device device-
number-1(device-
number-2) manage-
ment error. (Message
type: code1 Reason
code: code2 Error
code: code3code4,
cmd=xxx, pos=yyy)
YKZ258E TSO SC=8
The user SVC is not registered, or the &YKSVCNO system
symbol of the IEASYMxx parmlib member is specified
incorrectly.
When the user SVC is defined in SVCPARM:
Make sure that the &YKSVCNO system symbol of the
IEASYMxx parmlib member is specified correctly.
When the user SVC is not defined in SVCPARM:
Register the user SVC by YKALCSVC command.
For details about user SVC registration, see “Registering a
user SVC” on page 22.
SVC # is null or invalid.
YKZ300E TSO
SC=44 RC=44
The task is not authorized to execute P9000 mainframe
agent or the YKP2A command. If this message is displayed,
P9000 mainframe agent will not send storage information
to the P9000 Command View AE Suite products. If the
YKY680I message is output to syslog after this message,
the YKY680I message contains error information for the
command executed by P9000 mainframe agent (except the
YKP2A command).
For details about how to grant permission to execute P9000
mainframe agent or the YKP2A command, see “Setting up
the Resource Access Control Facility (RACF) when linking
with Replication Manager software” on page 28.
The task is not author-
ized to execute the re-
quest.
YKZ301E CON
RC=128
Mainframe Agent Installation and Configuration Guide 97