HP P9000 Command View Advanced Edition Software Mainframe Agent Installation and Configuration Guide

Explanation and actionsMessage textMessage ID
The dataset name of the P9000 mainframe agent load lib-
rary was not registered in SYS1.PARMLIB. Alternately, the
execution of the command failed because authorized/unau-
thorized datasets co-existed while concatenating DD state-
ments in the load library, and they were handled as unau-
thorized datasets.
The task is not APF-au-
thorized.
YKT032E CON
RC=20
The user SVC routine deletion succeeded.SVC routine is deletedYKT098I CON RC=0
The user SVC routine registration succeeded.SVC routine is insertedYKT099I CON RC=0
The command identified by command terminated with the
return code nnnn.
command command re-
turn code=nnnn.
YKT299I CON SC=0
The P9000 mainframe agent has started.
vv
Version number
rr
Revision number
zz
Exception
AGENT STARTED
(vv-rr[-zz])
YKY001I CON
The specified parameter has not been defined in the
initialization parameters, or the initialization parameter
shown as parameter-name is invalid. The P9000
mainframe agent has been terminated.
Correct the initialization parameters and then restart the
P9000 mainframe agent.
INVALID INITIALIZA-
TION PARAMETER:
parameter-name
YKY002I CON
The initialization parameters contain the specification for a
continuation line, but no parameter is continued. The P9000
mainframe agent will be terminated.
Correct the initialization parameters and then restart the
P9000 mainframe agent.
INVALID CONTINU-
ATION LINE FOUND.
PARAMETER SCAN
TERMINATED
YKY003I CON
The P9000 mainframe agent cannot start for the reason
indicated in the message that was displayed before this
message.
Contact the center administrator. The center administrator
must take appropriate action for the message that was
displayed before this message and then restart the P9000
mainframe agent.
termination-code (decimal number)
04: An attempt was made to start without using
IKJEFT01.
08: Initialization parameter analysis processing failed.
48: A process module loading error occurred.
52: A NAME/TOKEN write error occurred.
56: No profile is defined in the FACILITY class of the
RACF.
60: Subtask initialization processing failed.
AGENT INITIALIZATION
FAILED P=termination-
code
YKY005I CON