HP P9000 Command View Advanced Edition Software Mainframe Agent Installation and Configuration Guide

In the PREFIX parameter, do not specify any value other than the prefix of the configuration
file. If multiple datasets correspond to the specified prefix (such as the SYS1 prefix), P9000
mainframe agent processing might slow down.
Do not specify multiple PREFIX parameters for the same prefix. The monitoring processing
of Device Manager or Replication Manager software might slow down.
If you specify multiple PREFIX parameters, it will take time to switch the configuration files
for each prefix during a Replication Manager software request. Therefore, if there are many
configuration files, we recommend that you aggregate prefixes in the configuration files so
that there is only one PREFIX parameter, to shorten the access time for a request from or a
response to Replication Manager software.
Do not edit the configuration file for the prefix specified for the PREFIX parameter, as this
might cause display issues or errors with the P9000 mainframe agent configuration file inform-
ation in Replication Manager software.
The access time for a Replication Manager software request or response becomes longer ac-
cording to the number of copy pairs defined in the copy group definition file that has the
specified prefix. Therefore, specify the monitoring interval of Replication Manager software
to fit the environment (the host capability corresponding to the number of copy pairs).
DEVN(start-device-number,end-device-number) ~ <4 hexadecimal characters>
Specifies a range of devices from which to collect information when filtering the host volume in-
formation to be passed to Device Manager or Replication Manager software. Specify the start-
device-number and end-device-number in the ascending order of hexadecimal characters.
If the DEVN parameter has not been specified before, DEVN(0000,FFFF) is assumed.
Notes about Specifying the DEVN Parameter
To reduce the access time required for requests and replies from Device Manager or Replication
Manager software, we recommend that you specify a range of target devices from which in-
formation is collected.
When you specify more than one DEVN parameter, even if there are duplicate devices, they
are not eliminated, so make sure you avoid specifying such duplications.
LOGLEVEL(output-level) ~ <numeric character> ((0-2)) <<2>>
Specifies the log output level.
0
Logs are not output. If 0 is specified, it is difficult to determine the cause of a communication
failure or an error that occurs during execution of a P9000 mainframe agent command.
1
Communication-related messages (YKY300I, YKY301I, YKY304I, and YKY307I) are output.
2
In addition to the messages that are output when LOGLEVEL(1) is specified, a YKY680I
message indicating an error during execution of a P9000 mainframe agent command is
output.
The following table shows the LOGLEVEL specification and the messages that are output.
Table 8 LOGLEVEL specification and the output messages
Output messagesLOGLEVEL
No output
0
YKY300I, YKY301I, YKY304I, and YKY307I1
YKY300I, YKY301I, YKY304I, YKY307I, and YKY680I2
Setting up P9000 mainframe agent36