HP P9000 Command View Advanced Edition Software Mainframe Agent Installation and Configuration Guide
ActionEvent
Take appropriate action according to the dis-
played message.
A message other than those above is displayed.
Take appropriate action according to the return
code.
P9000 mainframe agent terminates with a return code
other than (00).
When information from P9000 mainframe agent is not updated
The table below lists the events and actions to be taken when information is acquired by using P9000
Command View AE Suite product, but the information from P9000 mainframe agent is not updated.
In the Event column, go down in the order listed and locate the first description that matches the event
that is occurring, and then use the action in the Action column to solve the problem.
Table 23 Events and what to do when information from P9000 mainframe agent is not updated
ActionEvent
The specified port number is in use. Either terminate the pro-
gram that is using the port number or change the port number
in the initialization parameter, then restart P9000 mainframe
agent.
The following message is displayed: YKY330I
SOCKET API FAILURE (OPEN,BIND,-
0000001,0000048)
Protected by RACF. Check and, if necessary, revise the RACF
settings, then restart P9000 mainframe agent.
The following message is displayed: YKY330I
SOCKET API FAILURE (INIT,INITAPI,-
0000001,0000156)
Protected by RACF. Check and, if necessary, revise the RACF
settings, then restart P9000 mainframe agent.
The following message is displayed: YKY330I
SOCKET API FAILURE (OPEN,BIND,-
0000001,0000013)
Make sure that the user SVC has been registered, then restart
P9000 mainframe agent.
P9000 mainframe agent has terminated ab-
normally with a system completion code (Fnn).
(Fnn: SVC number)
Take appropriate action according to the displayed message.
An error message is displayed on the console
or in SYSLOG.
Troubleshooting104