CVAE 6.0 to 7.0 Transition Overview (TB581-96076, June 2011)
If the conditions are not replaced with alternatives, the tier is not migrated after upgrading to V7.
V6
V7
• For those tiers, the tier information will be output to the following file. The file contains the filter conditions. Please
use alternative conditions to create V6 equivalent tiers.
• <installation-path>\CVXPAE\TieredStorageManager\logs\ TierInfo_NotSupported_y yyyymmddhhmmss.txt
• “yyyymmddhhmmss” is created date and time.
List of 1 StorageDomain elements
An instance of StorageDomain(1 of 1)
name=XP24000
controllerserialnumber=15060
controllerdisplaymodel=XP24000
controllername=XP24000@172.16.110.1
List of 1 StorageTier elements:
An instance of StorageTier(1 of 1)
name=LG-Tier2
resource=Volume
filtercondition=LogicalGroup = 'TierGroup/Tier2'
description=
cost=
chargefor=
thpcost=
thpchargefor=
Sample output
Use alternative conditions for the filter
condition defined in V6 to create a tier
- Alternative for Logical group condition
Search Condition to specify tier