HP XP P9000 for Business Continuity Manager Software Installation Guide
// SPACE=(TRK,(1,1,1)),DCB=*.INF3 Target library
//OUTF4 DD DSN=&TPFX..&TVRM..HPQYPRCT,
// UNIT=3390,VOL=SER=&TVSN,
// DISP=(NEW,CATLG,DELETE), PROCLIB
// SPACE=(TRK,(5,1,10)),DCB=*.INF4 Target library
//OUTF5 DD DSN=&TPFX..&TVRM..HPQYEXET,
// UNIT=3390,VOL=SER=&TVSN,
// DISP=(NEW,CATLG,DELETE), EXECLIB(F)
// SPACE=(TRK,(45,1,10)),DCB=*.INF5 Target library
//OUTF6 DD DSN=&TPFX..&TVRM..HPQYEXVT,
// UNIT=3390,VOL=SER=&TVSN,
// DISP=(NEW,CATLG,DELETE), EXECLIB(V)
// SPACE=(TRK,(45,1,10)),DCB=*.INF6 Target library
//OUTF7 DD DSN=&TPFX..&TVRM..HPQYPNLT,
// UNIT=3390,VOL=SER=&TVSN,
// DISP=(NEW,CATLG,DELETE), PANEL
// SPACE=(TRK,(60,1,200)),DCB=*.INF7 Target library
//OUTF8 DD DSN=&TPFX..&TVRM..HPQYMSGT,
// UNIT=3390,VOL=SER=&TVSN,
// DISP=(NEW,CATLG,DELETE), MESSAGE
// SPACE=(TRK,(5,1,5)),DCB=*.INF8 Target library
//OUTF9 DD DSN=&TPFX..&TVRM..HPQYTABT,
// UNIT=3390,VOL=SER=&TVSN,
// DISP=(NEW,CATLG,DELETE), TABLE
// SPACE=(TRK,(5,1,5)),DCB=*.INF9 Target library
//SYSIN DD *
COPY OUTDD=OUTF1,INDD=INF1
COPYMOD OUTDD=OUTF2,INDD=INF2
COPYMOD OUTDD=OUTF3,INDD=INF3
COPY OUTDD=OUTF4,INDD=INF4
COPY OUTDD=OUTF5,INDD=INF5
COPY OUTDD=OUTF6,INDD=INF6
COPY OUTDD=OUTF7,INDD=INF7
COPY OUTDD=OUTF8,INDD=INF8
COPY OUTDD=OUTF9,INDD=INF9
/*
SMPALLOC (allocating SMP/E datasets)
The method for modifying SMPALLOC, which allocates SMP/E datasets, is explained below.
The following numbers correspond to the numbers appearing on the right side of the sample JCL.
Modify the underlined portions in the sample JCL as follows:
(1)-(3)
Modify the JOB text to match the installation environment.
(4)
Change the prefix for the SMP/E dataset name from HPQYK to HPQ.BCM.
(5), (8)
Change the volume allocated to the SMP/E dataset from #smp01 to SMP001.
(6), (7), (9), (10)
Change the prefix for the dataset name from HPQYK. to HPQ.BCM.
//SMPALLOC JOB (ACCT#),'ALLO SMP FILES', -----(1)
// REGION=0M,CLASS=A, -----(2)
// MSGLEVEL=(1,1),MSGCLASS=X,NOTIFY=&SYSUID -----(3)
//*********************************************************************
//*
//* All Rights Reserved. Copyright (C) 2003, 2013, Hitachi, Ltd.
//*
SMPALLOC (allocating SMP/E datasets) 89