HP StorageWorks P9000 for Business Continuity Manager Software Installation Guide (T5253-96052, May 2011)
YKLCNS2=[prefix2] ~ <8 or fewer
alphanumeric characters>
Specify a prefix2 for the license
information dataset so that the name of
the dataset is unique. If the prefix2 is
omitted, specify PARM='YKLCNS2='.
For details about the prefix2 for the
license information dataset, see section
“Naming Conventions for License
Information Datasets” (page 44).
LOGPUT=[LOGR | SAM] Specify whether or not the system logger service
is to be used, when outputting BCM logs.
The specified value for the LOGPUT parameter is
given priority over the &YKLOGPT system symbol
in the IEASYMxx parmlib member. If this
command is executed with the LOGPUT parameter
omitted (PARM='LOGPUT=' is specified), the
value of the &YKLOGPT system symbol will be
used.
LOGR: BCM logs are output using the system
logger service.
SAM: BCM logs are output to sequential datasets.
SYSLOG=[YES | NO] Specify whether or not CLI command-execution logs
are output to SYSLOG.
The value specified for the SYSLOG parameter is
given priority over the &YKSYSLG system symbol in
the IEASYMxx parmlib member. If this command is
executed with the SYSLOG parameter omitted
(PARM='SYSLOG=' is specified), the value of the
&YKSYSLG system symbol will be used.
YES: CLI command-execution logs are output to
SYSLOG.
NO: CLI command-execution logs are not output to
SYSLOG.
For details about commands that collect CLI
command-execution logs, see the Hitachi
Business Continuity Manager User Guide.
Installing Business Continuity Manager 39