HP StorageWorks P9000 Mainframe Host Attachment and Operations Guide: P9500 Disk Array (AV400-96332, January 2011)
OWNERID(ZZZZZZZ)
/*
XXXX = physical install address, YYYYYY = new volume ID, ZZZZZZZ = volume ID owner.
Device operations: ICKDSF
The storage system supports the ICKDSF media maintenance utility. The ICKDSF utility can also be
used to perform service functions, error detection, and media maintenance. Because the P9000
disk array is a RAID device, there are only a few differences in operation from conventional DASD
or other RAID devices. The following table lists ICKDSF commands that are specific to the storage
system, as contrasted to RAMAC.
Table 10 ICKDSF Commands for P9000 Disk Array Contrasted to RAMAC
Return CodeStorage SystemArgumentCommand
CC = 12 Invalid
parameter(s) for device type.
RAMACKEEPITINSPECT
CC = 12, F/M = 04
(EC=66BB).
P9000 disk array
CC = 4 Parameter ignored
for device type.
RAMACPRESERVE
CC = 12, F/M = 04
(EC=66BB) Unable to
establish primary and
alternate track association
for track CCHH=xxxx.
P9000 disk array
CC = 4 Parameter ignored
for device type - skip.
RAMACSKIP
CC = 12, F/M = 04
(EC=66BB) Primary track
CCHH-xxxx found
unrecoverable.
P9000 disk array
CC = 0, ALT information not
displayed.
RAMACNOPRESERVE, NOSKIP,
CC = 0P9000 disk arrayNOCHECK
CC = 12 Invalid
parameter(s) for device type.
RAMACALLTRACKS, ASSIGN,
RECLAIM
In case of PRESERVE: CC =
12
In case of NO PRESERVE:
CC = 0.
P9000 disk array
CC = 0 (but not
recommended by IBM).
RAMACSETMODE (3390)INSTALL
CC = 0P9000 disk array
CC = 12, Invalid
parameter(s) for device type.
RAMACSETMODE (3380)
CC = 12, Function not
supported for
nonsynchronous DASD.
P9000 disk array
CC = 0RAMACANALYZE
CC = 0P9000 disk array
CC = 0RAMACBUILDX
Mainframe operations 29