HP StorageWorks P9000 Mainframe Host Attachment and Operations Guide: P9500 Disk Array (AV400-96332, January 2011)

| F1=Help F2=Split F3=Exit F9=Swap F12=Cancel |
'-----------------------------------------------------------------------'
4. On the Control Unit List panel, if a 2105 type of control unit already exists, then an Add
like operation can be used by inputting an A next to the 2105 type control unit and pressing
Enter. Otherwise, press F11 to add a new control unit.
Goto Filter Backup Query Help
--------------------------------------------------------------------------
Control Unit List Row 27 of 40
Command ===> ___________________________________________ Scroll ===> PAGE
Select one or more control units, then press Enter. To add, use F11.
/ CU Type + Serial-# + Description
_ 3107 SCTC __________ ________________________________
_ 3108 SCTC __________ ________________________________
_ 3109 SCTC __________ ________________________________
_ 310A SCTC __________ ________________________________
_ 4000 3990-6 __________ ________________________________
_ 4100 3990-6 __________ ________________________________
_ 4200 3990-6 __________ ________________________________
_ 4300 3990-6 __________ ________________________________
_ 5000 3990 __________ ________________________________
_ 5001 3990 __________ ________________________________
_ 6000 3990 __________ ________________________________
_ 6001 3990 __________ ________________________________
_ 7000 3990 __________ ________________________________
_ 7001 3990 __________ ________________________________
F1=Help F2=Split F3=Exit F4=Prompt F5=Reset F7=Backward
F8=Forward F9=Swap F10=Actions F11=Add F12=Cancel
5. On the Add Control Unit panel, input the following new information, or edit the information
if pre-loaded from an Add like” operation, and then press Enter:
Control unit number
Control unit type: 2105
Switch information only if a switch exists. Otherwise leave switch and ports blank.
.-------------------------- Add Control Unit ---------------------------.
| |
| |
| Specify or revise the following values. |
| |
| Control unit number . . . . 8000 + |
| |
| Control unit type . . . . . 2105_________ + |
| |
| Serial number . . . . . . . __________ |
| Description . . . . . . . . new 2105 type for 80xx devices__ |
| |
| Connected to switches . . . __ __ __ __ __ __ __ __ + |
| Ports . . . . . . . . . . . __ __ __ __ __ __ __ __ + |
| |
| If connected to a switch, select whether to have CHPIDs/link |
| addresses, and unit address range proposed. |
| |
| Auto-assign . . . . . . . . 2 1. Yes |
| 2. No |
| |
| F1=Help F2=Split F3=Exit F4=Prompt F5=Reset F9=Swap |
| F12=Cancel |
'-----------------------------------------------------------------------'
6. On the Select Processor / Control Unit panel, input an S next to the PROC. ID, and then press
Enter.
Goto Filter Backup Query Help
.---------------------- Select Processor / Control Unit ----------------------.
| Row 1 of 1 More: > |
| Command ===> ___________________________________________ Scroll ===> PAGE |
| |
| Select processors to change CU/processor parameters, then press Enter. |
| |
| Control unit number . . : 8000 Control unit type . . . : 2105 |
| |
| Log. Addr. -------Channel Path ID . Link Address + ------- |
| / Proc. ID Att. (CUADD) + 1---- 2---- 3---- 4---- 5---- 6---- 7---- 8---- |
| S PROD __ _____ _____ _____ _____ _____ _____ _____ _____ |
| ***************************** Bottom of data ****************************** |
| |
| |
| |
| |
| |
| |
| |
24 Mainframe operations