HP XP7 Command View Advanced Edition User Guide (TK981-96007, May 2014)

DescriptionSubfieldField
Periodic monitoring mode uses performance data from the last monitoring
cycle (see Cycle time). Tier relocation responds immediately to workload
changes. This mode is a more aggressive tier relocation monitoring mode.
Monitoring
mode
Periodic
For the XP7, you can select one of five speeds for the relocation of pages
in a pool, in a unit of time, from 1 (slowest) to 5 (fastest). The default is 3
(standard). To reduce the load on the storage system, specify a slower page
relocation speed. To give a higher priority to page relocations for the pool,
specify a faster relocation speed.
Relocation
Speed
Sets the buffer space used for new page assignments to Smart tiers (using
the default values is recommended).
Buffer Space for
New page as-
signment
Sets the buffer space used for tier page relocations between Smart tiers
(using the default values is recommended).
Buffer Space for
Tier relocation
NOTE:
After configuring the pools, click Show Plan and perform all of the confirming, scheduling, and
submitting tasks needed to create the pools.
Related topics
About virtualizing storage capacity, page 114
Creating a THP/Smart pool, page 115
Verifying THP/Smart pool information
You can check the THP/Smart pools summary information to verify the current number of pools, the
virtual volume capacity, the pools usage, and the total and used pool capacity.
Prerequisites
Create pools
Discover (register) pools
1. On the Resources tab, select THP Pools under the target storage system.
A list of THP/Smart pools, (THP/Smart pool volumes and THP/Smart volumes) provides summary
information that includes the number of pools, the virtual volume capacity, pool usage, and the
total and used pool capacity.