HP XP7 Command View Advanced Edition Release Notes (TK981-96008, May 2014)
If you perform an operation to refresh hosts or a copy pair operation on such a configuration, the
operation might generate one of the following error codes:
• KAIC90083-E (error code = 7757) An error was detected in the host agent.
(error details = "An unexpected error occurred during acquisition of
configuration definition file information. (error code = 6108)")
• KAIC90083-E (error code = 7774) An attempt to create a pair failed.
(host = <host-name>, error details = "A command device that can perform
user authentication exists in the storage system with the serial number
"<serial-number-of-storage-system>". (error code = 6140)")
• KAIC90083-E (error code: 7774) An attempt to create a pair failed.
(host = <host-name>, error details = ""An unexpected error occurred
during modification of a configuration definition file. (error code =
6110)"")
• KAIC90083-E (error code: 7774) An attempt to create a pair failed.
(host = <host-name>, error details = ""An error occurred during
modification of a configuration definition file. (error code = 6119)"")
• KAIC90083-E (error code: 7792) An attempt to acquire pair volume
information on the host ""<host-name>"" failed. (error details = ""An
error occurred during acquisition of configuration definition file
information. (error code = 6109)"")
If such a configuration exists, take the following actions:
1. Prepare a separate Device Manager agent to manage each storage system command device.
Alternatively, unallocate any unnecessary storage system command devices.
2. Enable user authentication for the command devices recognized by the host, and perform the
authentication operation from the Device Manager agent.
Creating Continuous Access Synchronous pair or Continuous Access Journal pair from
volumes in a virtual storage machine
A Continuous Access Synchronous or Continuous Access Journal pair cannot be created from the
following combination of volumes:
• A volume in a virtual storage machine
• A volume that exists in one of the following storage systems or corresponding virtual storage
machine
◦ P9500
◦ XP20000/XP24000
◦ XP10000/XP12000
Creating SMART Pools
When creating a SMART pool, if you can select a resource group in the Create Pool window, first
select the storage system and then the resource group, and then select SMART for the pool type.
If you select SMART for the pool type before selecting a resource group in the Create Pool window,
and then add a parity group in a mixed configuration, the window is not updated as follows:
• The graph shown for the Pool Summary is not updated.
• The Tier Configuration information is not updated.
Important considerations 9