◦ The data held by Element Manager can be synchronized.
◦ Roles that can be specified in Element Manager are supported by roles allocated to resource
groups in HP XP7 Storage
• Device Manager now supports HP XP7 Storage.
• The Device Manager GUI now supports display and configuration of Virtual Storage Machine in
HP XP7 Storage.
• The design of the Device Manager GUI was improved.
Fixes
The following issues were resolved in 8.0.0-00:
• In the Create Pool dialog box or the Edit Pool dialog box, if you customized the tier management,
selected the monitoring template, and then clicked the Submit button, the KAIC16993-E error
occurred and the task couldn't be executed. Alternatively, if you tried to edit the monitoring
template, the KAIC16993-E error occurred and the monitoring template couldn't be edited.
• When the ModifyReplication or DeleteReplication commands in CLI were used to
modify or delete a specific Fast Snap copy pair, the pvoldevnum parameter settings were
unintentionally not specified, and all the copy pairs in the Snapshot Group were modified or
deleted.
• The GetStorageArray command for Device Manager CLI generates the KAIC90083-E
(error code=3005) error message.
• Symptom 1: If the following procedure was performed, the KAIC15423-E or KAIC15467-E
occurred:
1. In the Added User window, a user with a user name of 256 characters was added.
2. In the Created User Group window, the user added in step 1 was allocated to the default
resource group or a user-defined resource group.
Symptom 2: After Symptom 1 occurred, an attempt to set the relations for the user group and
resource group generated the following errors:
◦ KAIC15422-E
◦ KAIC15423-E
◦ KAIC15467-E
◦ KAIC15470-E
◦ KAIC15131-E
Symptom 3: After Symptom 1 occurred, a system became unstable. For example, the state of
processing by DevMgr operations in general did not progress.
Symptom 4: After Symptom 1 occurred, if the DevMgr service was restarted, the KFPA11404-E
error occurred while the service was restarting, and the attempt to restart was unsuccessful.
• When you create a mixed smart pool, if you select a parity group, and then toggle between the
Internal Parity Groups tab and External Parity Groups tab in the Add Parity Groups window, the
Add to Pool button is enabled, and a parity group can be added.
• On an AIX host for which the ENV environment variable is set, an irrelevant error message is
displayed when starting or stopping the Device Manager agent service.
• The Elapsed Time is shown as negative numbers in the Tasks tab, the Task History tab, the
Completed Task List or the Failed Task List.
6 Fixes