HP XP7 Command View Advanced Edition 8.0.
© Copyright 2014 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice.
Version 8.0.0-00 Description This is the initial release of HP XP7 Command View Advanced Edition 8.0.0-00. For details, see “Enhancements ” (page 4). For previous behaviors resolved in this release, see “Fixes ” (page 6). For potential updates to these release notes, check the HP XP7 Command View Advanced Edition website: http://www.hp.com/support/cvae/manuals/ Update recommendation HP recommends updating to XP7 CVAE 8.0.0-00. Superseded version 7.6.
Enhancements Enhancements for 8.0.0-00: • The Device Manager server, GUI, and CLI now support the virtualization server product VMware vSphere ESXi 5.1 Update 2. For details on guest operating systems, see HP XP7 Command View Advanced Edition System Requirements. • The Device Manager server, GUI, and CLI now support Microsoft Windows Server 2012 R2 and Microsoft Windows 8.1. • Device Manager agent now supports guest operating systems running on the virtualization server product VMware vSphere ESXi 5.
• For P9500, Device Manager now supports the following host mode options: ◦ Round Trip Extended Set Up Option ◦ Change of the ED_TOV value These options can be specified when allocating volumes. • The Device Manager CLI now supports the importing and setting of volume labels and pool names for XP P9500. • From SCVMM2012 R2 on Windows Server 2012 R2 or Windows Server 2012 Power Shell 4.
◦ The data held by Element Manager can be synchronized. ◦ Roles that can be specified in Element Manager are supported by roles allocated to resource groups in HP XP7 Storage • Device Manager now supports HP XP7 Storage. • The Device Manager GUI now supports display and configuration of Virtual Storage Machine in HP XP7 Storage. • The design of the Device Manager GUI was improved. Fixes The following issues were resolved in 8.0.
• If you display the tiered THP Pool list for XP P9500 in the Mobility tab, THP Pools for which you do not have View permission are displayed. • In the Create THP Pool window, when you selected Smart for the pool type without first selecting a resource group, the incorrect message KAIC15232-E was displayed. • If the search condition category was set to "Security" and you used a saved search condition, the message KAIC15000-E appears, and the search cannot be performed.
Operations for storage systems while data collection tasks are executing If an operation is performed for a storage system that is the target of any of the following tasks, an unexpected error might occur: • Add Storage Systems • Refresh Storage Systems • Update Database (Auto) If an unexpected error occurs, check the task list to make sure that none of the preceding tasks is being executed.
If you perform an operation to refresh hosts or a copy pair operation on such a configuration, the operation might generate one of the following error codes: • KAIC90083-E (error code = 7757) An error was detected in the host agent. (error details = "An unexpected error occurred during acquisition of configuration definition file information. (error code = 6108)") • KAIC90083-E (error code = 7774) An attempt to create a pair failed.
If you then click the Show Plan button, the following information displayed for Plan Summary in the Create Pool window becomes invalid. • The percentages are not displayed for Used Threshold 1 and Used Threshold 2. • NoData is displayed for the Parity Group Information in the Plan Details.
Filtering by capacity or time When the equal sign operator (=) is used to filter by capacity or time, you might not be able to filter the results even if a value displayed in the list is used.
The value displayed for High Availability Manager In Device Manager, High Availability Manager (HAM) pair information is displayed as follows: • In the Device Manager GUI, the copy type of a HAM pair primary or secondary volume is displayed as "True Copy Sync". • In the Device Manager CLI, the pair information is displayed as "True Copy Sync" for replicationFunction for a ReplicationGroup instance or ReplicationInfo instance. Displaying the Ext. Storage Volume value in the parity group list The Ext.
Incorrect values for the Internal Storage Parity Groups column on the External Volumes tab If one of the following conditions is met, incorrect values for the Internal Storage Parity Groups column might be displayed on the External Volumes tab in the External Storage Systems window: • One external volume is mapped to an external parity group of multiple internal storage systems.
Externally connected volume GUI indication If you externally connect a volume that is already connected to externally to other storage systems, the information for the volume will not appear in the Device Manager GUI. The following example shows that the information about volume 2 does not appear in the Device Manager GUI, thus becomes inoperable. The information for volumes 1 and 3 will appear. • The volume 1 from storage system 1 is assigned to the storage system 2 as volume 2.
The Plan Confirmation window for unvirtualized volumes When you transition from the Unvirtualize Volumes dialog box to the Plan Confirmation window, the target parity group might not be displayed if there are already volumes that were unvirtualized . This issue does not occur if the storage system was refreshed to display the latest updated information. Discovering volumes for virtualization If there are many external volumes that are candidates for virtualization, volume discovery might take a long time.
If this issue occurs repeatedly, create a new Windows user account, and then use the new user account to operate the browser. Storage device virtualization tasks If a storage device virtualization task does not complete, volumes of an external storage system may remain allocated to an internal storage system. If you execute another storage device virtualization task for the allocated volumes, the attempt generates the error KAIC15001-E.
Using the Device Manager CLI: 1. Create a host group on the external storage port. 2. In the created host group, register the WWNs of the internal storage ports to be used to virtualize storage devices. Using Element Manager: 1. Create a host group on the external storage port. 2. In the created host group, register the WWNs of the internal storage ports to be used to virtualize storage devices. 3. Refresh the external storage systems by using the Device Manager GUI or CLI.
Adding storage system and launching Element Manager by using a host name (FQDN) When an FQDN is used to add storage systems or to launch Element Manager, the maximum length of the FQDN is determined by the following environments. • Adding storage system—The operating system of the server machine on which the Device Manager is installed. • Launching Element Manager—The operating system and the browser of the client machine.
Temporary shortcut folder after installation or removal (in Windows) After an installation or removal, a temporary shortcut folder named "programs" might be created under the Windows Start menu. After you log off and log on to Windows, this temporary shortcut folder no longer appears. Using Device Manager to update the information about a storage system Do not delete a host while the information about a storage system is being updated.
• LUN • File System • File System Used % • Virtual Port • Virtual Host Group ID Temporary solution Reduce the number of hosts registered for the logical group to be displayed. Recovery • Recovery when the KAIC16993-E message is generated as a result of the user sorting the data: Click the tree node to redraw the window.
JOB that unregisters Storage Logical Unit from the host when connected with SCVMM 2012 When executing the JOB that unregisters Storage Logical Unit from the host, the JOB generates error (2931). Cancel the allocated volume and manually update the information on SCVMM 2012 with the following procedure. 1. Log in to the object host to cancel the allocated volume. 2. When clustered with a built-in object volume, delete the object volume from the cluster manually. 3.
Importing the storage system labels to Device Manager When Refresh Labels (the operation to import the storage system labels to Device Manager) has over 20,000 volumes, do not the Refresh Labels at the same time as other tasks without considering the following factors: • • Confirm that there is no running task in Device Manager using one of the following methods: ◦ Display the Administration tab, then the Data Collection Tasks tab. ◦ Display the Task & Alerts tab.
Columns related to logical view: • IP Addresses Columns related to physical view: • WWN Columns related to system drives: • Host • WWN • Port • Host Group • LUN • Target ID • Copy Info (S-VOL) • Copy Info (P-VOL) • Parity Group • Volume Attributes Columns related to the Select THP Pool dialog box: • Volume Location • Drive Type • Drive Speed (RPM) • External LDEV Tier Rank Sorting and filtering columns The sort order of the following columns might not be correct.
• Drive Speed(RPM) • Total Capacity • Free Capacity • Usable Volumes • No. of Volumes THP pools columns: • Pool type • Subscription • No. of Parity Groups • Total Capacity Tiers columns: • Parity Group • Free Capacity • Tier No. • Volume Location • Drive Type • Drive Speed • No.
• Filesystem Used % • Vendor Parity groups columns: • Total Capacity THP pools columns: • Subscription Hosts columns: • OS AddLogicalUnit command in the Device Manager CLI When creating multiple LUs using the batch function in the AddLogicalUnit command, if the lusubinfo=LDEV option is specified for only a portion of the LUs to be added, the response of the command may be inconsistent in the following ways: • The information of the LU for which the option has been specified may not contain the correspo
If the specified search conditions or filter conditions meet either of the following conditions, pool volumes of the Snapshot pool and Fast Snap pool are mixed in the search results or filter results: • Volume search conditions or volume filter conditions include the condition "same as a Snapshot pool volume". • Volume search conditions or volume filter conditions include the condition "same as a Fast Snap pool volume".
As a result, all attributes specific to Smart Tiers for Mainframe (for example, tier information) cannot be viewed in Device Manager. Use Element Manager to view the attributes specific to Smart Tiers for Mainframe. Meter-based Term License When only the Meter-based Term license is registered, an Emergency license cannot be input.
AddExternalArrayGroup command of Device Manager CLI KAIC90083-E Device Manager Exception: error code=6450 error level=2 error source=StorageManager.AddExternalArrayGroup description=An error occurred during processing on the storage system. (error code 1 = "605", error code 2 = "66744", meaning = "It is not set within the range where LDEV capacity can be used.") If the configuration was being changed, refresh both the storage system and external storage system.
Inaccurate error messages in the tier relocation starting operation for Smart pool when using manual mode If an error occurs in the tier relocation starting operation for a Smart pool when using manual mode, the following inaccurate error messages may be output. • • In the CLI, if the tier relocation starting operation is executed for a Smart pool that is not multi tier configuration, the following error message is output.
available LU number. Even though the LU number candidate is chosen with auto or manual in LU Number, the candidate might not be used. If you need to use a specific LU number for a volume, use Remote Web Console.
When the OK button is clicked repeatedly in the Create Logical Groups dialog box, multiple logical groups with the same name might be created. If this occurs, delete the groups except one. When the OK button is clicked repeatedly in the Delete Logical Groups dialog box, the KAIC15158-E message might appear. If this occurs, ignore the message because the logical group was properly deleted. Search screen The search condition that includes the storage system name cannot be displayed again.
KAIC16902-E message with no summary information in the main window during any operation in the GUI During any operation in the GUI, the KAIC16902-E message appears in the top window and the Summary information does not appear in the main window. If this occurs, close the error dialog box and continue the operation. If you need the summary information, log in to Device Manager again.
The volume virtualization using the existing path group generated the following messages: • GUI: DevMgr 7.0.0-00 or later: KAIC06450-E • CLI: HDvM 6.1.0-00 or later: KAIC90083-E (error code: 6450) Do not change the path group setting using XP P9000 Remote Web Console or XP Remote Web Console. Allocating volumes to many hosts Operations in the Allocate Volumes dialog box cannot continue and the GUI is grayed out if the following conditions are met: • Device Manager 7.2.1-02 or later is used.
To launch Element Manager properly, assign the certificate whose IP address is correctly set to the Common Name of the certificate in the XP P9500 disk array. KAIC15306-E error in Create Volumes dialog box While the KAIC15306-E error is occurring in the Create Volumes dialog box, even if the Initial LDEV ID is changed, the Show Plan button cannot be enabled and the plan cannot be displayed. If this occurs, open the Create Volumes dialog box again.
Volume search: Search results might not be correct if is not is specified as a conditional equation in volume search by label. Only volumes assigned labels can be searched. If this occurs, sort the volumes by the Label column after filtering candidate volumes by attributes other than Label. Displaying capacity of hosts When the capacity of hosts is changed by Create LUSE Volumes or Expand THP Volumes, the capacity of hosts is not refreshed.
/Winexe /HostDataCollector/conf/HDCPid.dat Delete them manually after the removal. Host Data Collector can be reinstalled if these files or directories remain. Using Host Data Collector to register Linux hosts If a user who is using a login shell other than the default shell registers or refreshes hosts, the operation might generate the error ERR_1310. The user must use the default login shell.
Public search conditions If saved search conditions contain a resource that a user cannot view, the search conditions might appear incorrectly. If this occurs, and then the Search button is clicked, the displayed search results might differ from the saved search conditions. This issue occurs when either of the following conditions is met: • A resource for which the user does not have the view permission is specified for the saved search criteria.
4. Import the database. 1. Execute the hcmdsdbtrans command to import the databases: \Component\bin\hcmdsdbtrans /import /workpath /file /type ALL /auto 2. Specify true for the server.base.initialsynchro property on the Device Manager server. Other than user information, the hcmdsdbtrans command does not migrate the Common Component repository.
Shrinking a pool An unexpected error (KAIC60003-E) might appear without the message when using shrink pool. If this occurs, confirm if the task of shrink pool has completed in Element Manager. If the shrink pool task has completed in Element Manager, execute the format task. Refresh the storage system by using the Command View Advanced Edition Software after the format task completes.
Parity groups in the Create Volume dialog box The following message appears if the Create Volume dialog box is opened when all of the parity groups are reserved: No parity groups for create volumes. Create a parity group. (KAIC16109-E) If this occurs, wait until the task using the parity groups ends. Virtual Parity Group information Virtual Parity Group information does not appear in the volume list. Check the Virtual Parity Group information from the Detailed Information dialog box for each volume.
Warning banner settings When you create warning banner messages using the hcmdsbanner command, only the following HTML tags can be used for warning banners:
Creating and allocating volumes The following items cannot be filtered in the Select THP Pool dialog box: • Used Capacity • Subscription Allocate Volumes dialog box and Unallocate Volumes dialKAIC16009-E If this occurs, log in again. Task status in the Task Details dialog box If the Device Manager service stops while a task is executing, even if the status of the task changes to the Failure status, the Status column in the Task Details dialog box might display Waiting. If this happens, any tasks whose status appears as Waiting in the Status column are not performed, so create the tasks again as necessary.
Allocating volumes In the Allocate Volumes, Allocate Like Volumes, or Add Storage for vCenter Plug-in combo dialog box, if the number of pools or volumes in a storage system is large and Any is selected from the storage system combo box, the KAIC15005-E error might occur and the selection of volumes that meet the conditions might not succeed. If this occurs, allocate volumes after selecting a storage system in the Resources tab.
Enabling SSL between the Device Manager server and management clients when using Firefox To enable SSL4 between the Device Manager server and management clients by using Firefox, perform the following operations: 1. Disable SSL between the Device Manager server and management clients. 2. Register the license files. 3. Enable SSL between the Device Manager server and management clients.
Virtualizing storage devices If you perform a volume virtualization task created under all of the following conditions in the Virtualize Volumes dialog box, the task generates a KAIC15001-E error: • The external paths are set to the volumes that are selected when you launch the Virtualize Volumes dialog box. • Both of the ports on the internal storage side and external storage side in the external paths described in the first condition are selected.
• 20(FTP Data) • 21(FTP Control) • 22(ssh) • 23(telnet) • 25(smtp) • 37(time) • 42(name) • 43(nicname) • 53(domain) • 77(privrjs) • 79(finger) • 87(ttylink) • 95(supdup) • 101(hostriame) • 102(iso-tsap) • 103(gppitnp) • 104(acrnema) • 109(pop2) • 110(pop3) • 111(sunrpc) • 113(auth) • 115(sftp) • 117(uucp-path) • 119(nntp) • 123(ntp) • 135(loc-srv / epmap) • 139(netbios) • 143(imap2) • 179(bgp) • 389(ldap) • 465(smtp+ssl) • 512(print / exec)
• 540(uucp) • 556(remotefs) • 563(nntp+ssl) • 587(smtp) • 601(syslog) • 636(ldap+ssl) • 993(ldap+ssl) • 995(pop3+ssl) • 2049(nfs) • 4045(lockd) • 6000(x11) GUI operations after upgrading Device Manager After upgrading Device Manager, reboot the browser used as the GUI or clear a cache of the browser, and log into Command View Advanced Edition Suite products. If the above operation is not performed, the GUI might be inoperative.
Setting and using storage resource access control If any of the following operations are performed, and then other Device Manager operations are performed, the windows might appear incorrectly or a KAIC15001-E error might occur. If this occurs, restart the Device Manager server. • Storage resource access control is simultaneously specified for multiple users.
Registering and refreshing hosts The KAIC169001-E message might appear when communications between Host Data Collector and target multiple hosts are not successful in registering or refreshing hosts. If this occurs, close the browser and then log in again five minutes later. When HiRDB is installed in the system During Common Component installation, HiRDB will be installed as the database management system.
in which socket connections are blocked on the local host. When setting up a firewall in the operating system, configure the settings so that socket connections are not blocked on the local host. TMP environment variable (Windows) If multi-byte characters are included in a Windows login account name, they will also be included in the path specified in the TMP environment variable, and you will not be able to install the Command View Advanced Edition Suite.
Prerequisites Superseded version 7.6.1-02 See the HP XP7 Command View Advanced Edition System Requirements for complete product requirements. Applicable product version 8.0.
Device Manager Software 8.0.0-00 • HP XP7 Command View Advanced Edition System Requirements (TK981-96010) Version 8.0.0-00 • HP XP7 Command View Advanced Edition Installation and Configuration Guide (TK981-96001) Version 8.0.0-00 • HP XP7 Command View Advanced Edition Administrator Guide (TK981-96006) Version 8.0.0-00 • HP XP7 Command View Advanced Edition CLI Reference Guide (TK981-96006) Version 8.0.0-00 • HP XP7 Command View Advanced Edition User Guide (TK981-96007) Version 8.0.